background image

T8-S Topside

Installation Manual & User’s Guide

For C5 Series Spa Controls with the T8-S Topside

Revision 06.19

Summary of Contents for C5 Series

Page 1: ...T8 S Topside Installation Manual User s Guide...

Page 2: ...opside s programming as mis programming can result in malfunction or possible damage Please contact your dealer or a locally licensed service center for service and technical support Warranty Disclaim...

Page 3: ...Disclaimers 1 Safety 4 For Qualified Service Professionals Only T8 S Topside Installation 7 About The T8 S Topside 8 Using The T8 S Topside 9 For Qualified Service Professionals Only T8 S Topside Init...

Page 4: ...eat Mode 17 Time Settings 17 Filtration Settings 18 Interface Settings 19 Lock Operation 19 Operation Instructions 20 Temperature Operation 20 Toggling Display Orientation 22 Operating Pump 1 23 Opera...

Page 5: ...VERTISSEMENT POUR VITER QUE LES CHEVEUX OU UNE PARTIE DU CORPS PUISSENT TRE ASPIR S NE PAS UTILISER UNE CUVE DE RELAXATION SI LES GRILLES DE PRISE D ASPIRATION NE SONT PAS TOUTES EN PLACE 3 Warning Pe...

Page 6: ...ssibly pregnant women should consult a physician before using a spa or hot tub AVERTISSEMENT LES FEMMES ENCEINTES QUE LEUR GROSSESSE SOIT CONFIRM E OU NON DEVRAIENT CONSULTER UN M DECIN AVANT D UTILIS...

Page 7: ...uction ATTENTION LA TENEUR DE L EAU EN MATI RES DISSOUTES DOIT TRE CONFORME AUX DIRECTIVES DU FABRICANT 14 Hyperthermia occurs when the internal temperature of the body reaches a level several degrees...

Page 8: ...be cut out of the shell of the hot tub for installation as shown Once ready to install plug one end of the topside cable into the back of the T8 S snake the cable through the cutout in the shell and...

Page 9: ...rol box The T8 S is pictured below with the descriptions of the items that will be referenced throughout this user s guide 10 LED Display 20 Jets 1 Button Indicator Light 30 Aux Button Indicator Light...

Page 10: ...while it starts up All configurable settings are saved to permanent memory the only thing that needs to be set upon power up of a T8 S topside that has already been configured previously is the curre...

Page 11: ...consisting of five codes that configure what components the system will operate and what maximum amperage the system will operate at Each code has a number of options that the code can be set to By d...

Page 12: ...tion No heat with P 2 Option 4 40A Operation No heat with P 2 and Aux Option 5 20A 120V Operation or 30A 240V Operation No heat with anything other then P 1 Lo Speed Code 5 Heater Operation Option 1 E...

Page 13: ...o taking longer then 10 seconds between steps will cause the topside to time out and resume normal operation Step 1 Press Hold for 15 seconds until the display will reads Step 2 Press Hold for 15 seco...

Page 14: ...be visible selectable This means you have another code set to an option that conflicts with the missing option So if you program the topside to use the Jets 2 button to operate a two speed Pump 2 you...

Page 15: ...tween and making changes to these settings which will be referenced throughout this section Entering the User Settings Menu Step1 Press Hold for 15 seconds until the display will reads Step 2 Press to...

Page 16: ...next page Press Hold Time System Time Press to view change thru thru thru Filter Cycle 1 Start Time Press to view change Filtration thru Start Time 12am 11pm Press to change Cycle Duration 0 12 hours...

Page 17: ...ser Interface Temperature Scale Press to view change or Fahrenheit Celsius Time Display Press to view change or Beep on Keypress Press to view change or Temp Lock Press to view change or Lock Set Temp...

Page 18: ...temperature falls below the set heat temperature the Heat indicator light will flash to let you know that the unit would be heating if not in Economy Mode Note On spas with Circulation Pumps that run...

Page 19: ...ime for hye cycle Pressing Temp Up will show the currently set cycle duration which can be set from 0 hours no cycle to 12 hours by pressing Temp Up as many times as needed to reach the desired settin...

Page 20: ...just shows the current temperature during normal operation Beep on Keypress BEEP By default the T8 S topside will sound an internal buzzer when a button press is registered Simply toggle this code to...

Page 21: ...perature You can press and release right away to raise the setting incrementally by one degree or keep the button pressed to scroll through higher temperature settings and release the button once the...

Page 22: ...the indicator light between the temp buttons will be lit and the display will flash between the current temperature and HEAT as shown If the indicator light between the temp buttons is flashing this...

Page 23: ...tandard operating display when the display is showing the current temperature time To toggle the screen orientation simply press and hold the Aux button until the display reads PL 1 then press and hol...

Page 24: ...on Dual or Triple Pump Systems Press to toggle between Lo Speed Hi Speed Off When Hi Speed of Pump 1 is running the Jets 1 indicator light will be lit When Lo Speed of Pump 1 is running the Jets 1 ind...

Page 25: ...Pump 2 or dual speed Pump 2 Single Speed Pump 2 Operation Press to toggle between On Off Dual Speed Pump 2 Operation Press to toggle between Lo Speed Hi Speed Off When Hi Speed of Pump 2 is running th...

Page 26: ...30 minutes of operation Operating the Spa Light To operate the spa light simply press to toggle between On Off The light will automatically shut off after 4 hours of operation Note If your spa also ha...

Page 27: ...ll display briefly when Lo Speed of Pump 2 is activated Hi Speed Pump 3 This message will display briefly when Hi Speed of Pump 3 is activated Air This message will display briefly when the air blower...

Page 28: ...emperature sensor is malfunctioning or not properly connected Reconnect or replace temperature sensor as needed Hi Limit Sensor Error The hi limit sensor is malfunctioning or not properly connected Re...

Page 29: ...iration date of this warranty Processing claims should be initiated by the point of purchase or the installing dealer 2 A Return Merchandise Authorization RMA form must be completed and submitted to U...

Page 30: ...United Spa Controls 5614 E La Palma Ave Anaheim CA 92807 Web UnitedSpaControls com E mail support unitedspacontrols com Phone 714 982 0170 Fax 888 715 0286 2019 United Spa Controls All rights reserved...