![United Electric Controls UE VANGUARD WirelessHART TCD60HXY Installation And Maintenance Instructions Manual Download Page 10](http://html1.mh-extra.com/html/united-electric-controls/ue-vanguard-wirelesshart-tcd60hxy/ue-vanguard-wirelesshart-tcd60hxy_installation-and-maintenance-instructions-manual_4498193010.webp)
WirelessHART Toxic & Combustible Gas Detector
IM_TCD60-01
www.ueonline.com/vanguard
7
6. When hardware and software boot-up is complete, the device will prompt user to activate the installed sen-
sor (see Figure 7)
Refer to section 2.2 for sensor activation sequence.
7. Once activation is done, the front panel display will display the device name, HART long tag, and the software
version, along with an instruction to push button to show gas concentration (see Figure 8).
8. The device is now ready to be configured for deployment into a WirelessHart network. It is recommended to
connect the device to the network immediately after battery installation to maximize battery life. Refer to
section 2.8 for network configuration.
9. Once device configuration is complete, secure cover onto enclosure by tightening until all threads have been
fully engaged to ensure proper ingress protection.*
*
NOTE: To ensure proper ingress protection, the rear cover must be installed, and fully bottomed out against the base
enclosure (i.e., metal-to-metal contact). It is recommended to use a wrench or any tool across the cover lugs to tighten the
covers down.
VANGUARD
SENSOR NOT
ACTIVATED : CH4
PUSH BUTTON TO
ACTIVATE SENSOR
Figure 7
SW VER: X.XX
VANGUARD
SENSOR: CH4
TAG : KANBAN XXXXXX
PUSH BUTTON TO
SHOW CONCENTRATION
Figure 8