Model No. : UT-1405

PAGE : 3

FDA 21 CFR part 11 - GAMP-4 compatible.

LEDs. S

both

Microcontroller based indicator with inbuilt Temperature & DP measurement in single enclosure.
Incorporates highly stable built-in or Remorte Temp. & DP sensor.
3 Digit, 0.56" bright LED display for displaying Temperature and DP
Process parameter Hi and Low

tatus indication For

channel.

User selectable set limits for process value violation.
Inbuilt buzzer to audible process value violation.
Password protection for calibration and programming mode.
Software Calibration for both channels.
MODBUS RTU multi drop RS-485 serial communication for PLC, SCADA, etc.
Programmable devise address, baud rate, (max no. of device is 1-256).
Remote programmable from master device.
User programmable offset correction.
Compact, All Stainless Steel enclosure with 35 mm depth for installation in prefab panels.
Brick and modular wall mounting and flush mounting.
FDA21 CFR part 11 compliance data logging software available
Ex. Flameproof model available for Hazardous applications.

Technical Specification

Flame

Proof

Material of constructions

Cable entery

Gas group

Enclose certification

Display glass

Degree protection

I IIA IIB as per IS 2148/1981

Enclosure is certifies by C.M.R.I. dhanbad

Clear glass thognet type A as per Is 2206

IP 65 as per IS 2147

5 x 3/4 “ ET

Aluminum alloy

Technical data

Nos. of input

Input

Indication

Range

Accuracy

Transmitter power supply

Comunication

Programmable

Parameters

Other

Supply voltage Power consumption

24 v DC @ 4 watts maximum

Operating ambient temperature and humidity

Temperatures input

2 nos .(TEMP + DP)

- 0~50 °C

- Below 90%, non condensing

Mounting

Bricks and modules wall Flush panel mounting.

DP input

Integral Or Remote (external)

Integral Or Remote (external)

24V/5V DC @ 30 mA max, isolated from I/p & O/P.

Temperatures

DP

Channel-1 : 3 digit Seven segments 0.56” RED display.

Channel-2 : 3 digit Seven segments 0.56” RED display.

LEDs for visual alarms, Buzzer for audible alarm, LED for 485-comm.

Temperatures

0 to 60.0 *C with decimal point.

Display Resolution

Temperatures

0.25 % on FS

Response time : 8 sec

Status indication

Read /write parameter

Read: Procces value ,decimal point. Write: Hi Low set point.

Programmable parameter

Modbus RTU RS- 485 Isolated communications.

Baud rate , Parity , Node address , stop bit.

Communication Protocol

Full range as per input selection.

Programming of parameters

Through 4 tactile keys (with password protections)

No. of slave ID

Total 1-256 unit.

Alarm logic

Full Scale HI OR Full scale Low

MOC

Full S S 316 plate and box , back side wall mounting M S covers.

Set point / High scale / Low scale

-10 to 10 mm / -25 to 25mm / -100-100 mm /-200 to 200 mm wc

mm wc : 0.1 / PA : 1 / Hpa :0.01

1 % on FS in all unit

Response time : 1 sec

DP

DP

Summary of Contents for UT-1405

Page 1: ...MANUAL z TEMP P INDICATOR 91 94273 01436 Sales www utplindia in Website Sure for service with hi end versal nology Uni Tech Sure for service with hi end versal nology Uni Tech E mail sales utplindia...

Page 2: ...atures Micro based design Elegant appearance easy to operate and compact in size Highly accurate and sturdy in operation T display for simultaneous indication of T processor wo P RS 485 Communication...

Page 3: ...igit or value in Programming Mode Acknowledgment of Buzzer ring at Low High Values of C Rh and P Red LED will glow on high Process values of C P Press to change Rh Set point in Normal Mode and to chan...

Page 4: ...certification Display glass Degree protection I IIA IIB as per IS 2148 1981 Enclosure is certifies by C M R I dhanbad Clear glass thognet type A as per Is 2206 IP 65 as per IS 2147 5 x 3 4 ET Aluminum...

Page 5: ...RMINALS ARE NOT AVAILABLE TEMP RH SENSOR 4 Wire TEMP HUMIDITY SENSOR WITH WIRE CODE T RH SENSOR YELLOW BLACK RED GREEN T RH SENSOR YELLOW BLACK RED GREEN 91 94273 01436 Sales www utplindia in Website...

Page 6: ...Prs non 1tY PAr Password Protected Ct1 445 Ct7 Mxf 518 oFF tm 000 oFF Pr 000 Mnf MOD set 000 Ent pas 200 sp1 tmp tmp sp2 Prs sp2 sp1 Prs 400 020 050 UP Password Protected 1br MOD CAL 000 Ent pas Lo P...

Page 7: ...e Buzzer on this value Lo AL2 prs Active in Low Lo Lo Active in Very Low vLo Active in Very High vH1 Active in High H1 Disabled dsb 01 Add nod Node Address Node address for Communication Scroll the di...

Page 8: ...ey SETUP MODE PARAMETER Temperature Alarm 1 Set point Values between Set point for buzzer activation 000 to 999 Scroll the digit by key increase by key Temperature Alarm 2 Set point Values between Set...

Page 9: ...rameter Description Range Default Value Password for Parameter Setting Values between Password for Configuration Parameter 000 to 999 Scroll the digit by key increase by key 000 Ent pas Pressure Low C...

Page 10: ...re Check power lines connection Check Control Supply Voltages Replace keypads OPEn ERROR MESSAGE AND TROUBLESHOOTING z z REGISTER ADDRESS FOR MODBUS RTU PROTOCOL z z SR NO PARAMETERS ABSOLUTE ADDRESS...

Page 11: ...www utplindia in Website Sure for service with hi end versal nology Uni Tech Sure for service with hi end versal nology Uni Tech E mail sales utplindia in Add 78 1 Z 3 Makarpura GIDC Makarpura Vadodar...

Page 12: ......

Reviews: