Double confirm:
If it is enabled,
the image
platform will
require a several times of same-decoded-data to confirm a valid reading.
Global Max./Min. code length for 1D symbol:
These two lengths are defined as the valid range
of decoded 1D barcode data length. Make sure that the minimum length setting is no greater than
the maximum length setting, or otherwise the labels of the symbol will not be readable. In
particular, the same value can be set for both minimum and maximum reading length to force the
fixed length barcode decoded.
Notes:
1. Please set the max./min. length for individual barcode in later sections, if special demand is
requested.
2. The number of check digits is included in max./min. code length.
3. These two settings have no effect on the symbols with fixed-length, e.g. UPC-A, UPC-E, EAN-
13, EAN-8 and China Post.
Global G1-G6 string selection:
The image platform offer one or two string group for all symbols.
By setting one or two digits to indicate which string group you want to apply. You may refer to
3-42
G1-G6 & C1-C3 & FN1 substitution string setting
and
3-43 G1-G4 string position & Code ID
position
.
Example: Group 1
→
set 01 or 10. Group 2 and 4
→
set 24 or 42.
All valid settings include 00, 01, 02, 03, 04, 05, 06, 10, 11, 12, 13, 14, 15, 16, 20, 21, 22, 23, 24,
25, 26, 30, 31, 32, 33, 34, 35, 36, 40, 41, 42, 43, 44, 45, 46, 50, 51, 52, 53, 54, 55, 56, 60, 61, 62,
63, 64, 65 and 66.
Element amendment:
If it is enabled, the image platform can read the barcode comprised with
bars and spaces in different scale.
Character output restraint:
Printable character only-
If this option is selected, the image platform will output the printable
characters only, i.e. in ASCII from 20H to 7EH.
Alphanumeric character only-
If this option is selected, the image platform will output the
alphanumeric characters only, i.e.
“A”-“Z”, “a”-“z”, “0”-“9”.
Decoder optimization:
If it is enabled, the image platform will optimize the decoder with error
correction. This function is not effective for all types of barcode.
Data output delay in continue-scan mode:
If it is enabled, in the continue-scan mode, the image
platform can store the data while continue-scanning. The image platform will output the data after
the predefined delay elapsed. The maximum storage of data is 1000 characters. If this parameter
is set to be
“00”, the image platform will not store data. And if the parameter is set to be “FF”, the
image platform will output data after stopping scanning.
Character encoding system:
A character encoding system consists of a code that pairs each
character from a given repertoire. Common examples include Morse code, the Baudot code, the
ASCII and Unicode. If the data received does not display with the proper characters (domestic
language, e.g. Chinese), it maybe because the barcode being scanned was created using a
character encoding system that is different from the one the host program is expecting. Try
alternate options to find the proper one.
Summary of Contents for PS8000
Page 1: ...PS800 Presentation Imager User Manual...
Page 2: ......
Page 4: ...Unitech Europe Form PS800 Version 1 1 1...
Page 6: ...Unitech Europe Form PS800 Version 1 1 1...
Page 12: ...6 2 2 Dimensions...
Page 13: ...7 2 3 Parts of the imager Figure 2 2 Trigger Scan window Beeper...
Page 17: ...11...
Page 44: ...38...
Page 47: ...41...
Page 59: ...53 Multiple scan setting Single scan setting Option barcode Option Alpha entry Enable 01...
Page 64: ...58...
Page 73: ...67 Insert group selection 00 66 00 66 00...
Page 75: ...69 Conversion None 00 UCC EAN 128 01 UPC A or EAN 13 02...
Page 78: ...72 UCC EAN 128 01...
Page 92: ...86 Testing barcode...
Page 96: ...90...
Page 105: ...99 Interleaved 2 of 5 Industrial 2 of 5 Default setting Read disable Matrix 2 of 5 Code 93...
Page 108: ...102 Aztec Code 12345678901234567890 Han Xin Code 12345678901234567890...
Page 111: ...105...