MSR120 Programmer’s Manual UDN PM010, Rev. 1.1
Section 5 – Configuration Commands 2003/1/21
s1 (46h 61h x)
!
Set Track 1 Suffix Code
1 Suffix can be set as 1-6 characters
2 If first character = 00h, suffix code of track 1 will not be send. It means this function is disabling.
Table 5-12. Set Track 1 Suffix Code
Command Form (Hex)
Track 1 Suffix Code
09h 00h 03h 73h 31h 00h 48h
Disable (default)
Example of Track 1 Suffix Code Setting
09h 00h 03h 73h 31h 06h 4Eh
One character: 06h
s2
data
(73h 32h
data
)
!
Set Track 2 Suffix Code
1 Suffix can be set as 1-6 characters
2 If first character = 00h, suffix code of track 2 will not be send. It means this function is disabling.
Table 5-13. Set Track 2 Suffix Code
Command Form (Hex)
Track 2 Suffix Code
09h 00h 03h 73h 32h 00h 4Bh
Disable (default)
Example of Track 2 Suffix Code Setting
09h 00h 03h 73h 32h 06h 4Dh
One character: 06h
s3
data
(73h 33h
data
)
!
Set Track 3 Suffix Code
1 Suffix can be set as 1-6 characters
2 If first character = 00h, suffix code of track 3 will not be send. It means this function is disabling.
Table 5-14. Set Track 3 Suffix Code
Command Form (Hex)
Track 3 Suffix Code
09h 00h 03h 73h 33h 00h 4Ah
Disable (default)
Example of Track 3 Suffix Code Setting
09h 00h 03h 73h 33h 06h 4Ch
One character: 06h
K1A
type start end
(4Bh 31h 41h
type start end
)
!
Set Transmitting Data Block, Channel A of Track 1
where
type
means card type,
start
means start address of transmitting data, and
end
means end address of
transmitting data.
1 (31H) CA old DMV
2 (32H) AAMVA
3 (33H) ISO
4 (34H) JIS
6 (36h) Trade Show
Page 5-4
Proprietary and Confidential
Total 36 pages