50
© 2016 unitech Electronics Co., Ltd. All rights reserved.
unitech is a registered trademark of unitech Electronics Co.,Ltd
MS912+ User’s Manual
4.5 Beep tone, Terminator
BEEP TONE
2.7KHz Buzzer
TERMINATOR
BEEP OFF
NONE
BEEP HIGH
LF
BEEP HIGH-LOW
CR *
BEEP MEDIUM *
CR+LF *
BEEP LOW-HIGH
TAB
BEEP LOW
SPACE
ESC
Note: Below is the position of Terminator among output data string:
[Preamble] [Symbology ID] [Barcode Length] [Barcode Data]
[Postamble] [Terminator]
By default, with Preamble, Postamble, Barcode Length and Symbology
ID disabled, the scanner data output will be:
[Barcode Data] [Terminator]
1. For the Keyboard Wedge interface the default terminator is CR.
2. For the USB interface the default terminator is CR.
3. For the RS232 interface the default terminator is CR+LF.