background image

46

5.2.13 MSI

Restore Factory Defaults

Restore the Factory Defaults of MSI (default)

Enable/Disable MSI

Enable MSI

Disable MSI (default)

Message Length

Message length can be set to the maximum value, minimum value. The data is valid

between the maximum and the minimum.

The maximum value and minimum value can be set using Programming command.

Please check the programming command guide for the detail.

MSI max length command: 020E04. The parameter of this command can be set from min

to 48.

MSI min length command: 020E03. The parameter of this command can be set from 4 to

max.

Example: Set the Barcode Message length of the minimum value is 10; the maximum

value is 25.

Programming command

Max: 020E0425.

Min: 020E0310.

Summary of Contents for MS846

Page 1: ...1 MS846 User s Manual Version 1 0 Unitech 2D Image Scanner...

Page 2: ...n 14 3 1 Trigger Mode 14 3 2 Continue Mode 14 3 3 Cellphone Mode 15 3 4 Inverse color 16 3 5 Illumination 16 3 6 Beeper Good Read 16 3 7 Beeper Tone Good Read 17 3 8 Beeper Duration Good Read 17 3 9 B...

Page 3: ...45 5 2 13 MSI 46 5 3 2D Symbologies 48 5 3 1 PDF 417 48 5 3 2 QR Code 50 5 3 3 Data Matrix 52 5 3 4 Maxi code 53 5 3 5 Aztec 54 5 3 6 Hanxin 56 5 4 Postal Symbologies 57 5 4 1 China Postal Code 57 5 4...

Page 4: ...orm or by any electrical or mechanical means such as photocopying recording or information storage and retrieval systems without permission in writing from the manufacturer The material in this manual...

Page 5: ...anual The MS846 features fast scanning and decoding accuracy Barcodes rotated at any angle can still be read with ease When scanning a barcode simply center the aiming beam or pattern projected by the...

Page 6: ...evice can receive scanned data and send commands to control the engine or to access alter the configuration information of the engine via the TTL 232 or USB interface 2 1 TTL 232 Cable Select Before u...

Page 7: ...l communication interface provided by the engine is based on TTL level signals TTL 232 can be used for most application architectures For those requiring RS 232 an external conversion circuit is neede...

Page 8: ...its of data transmitted per second Set the baud rate to match the Host requirements 2400 4800 9600 19200 38400 57600 115200 default 2 4 Data Bit Parity Check Stop Bit None Parity 8 Data Bits 1 Stop Bi...

Page 9: ...a Bits 1 Stop Bit Odd Parity 7 Data Bits 2 Stop Bit 2 5 USB HID KB When you connect the engine to the Host via a USB connection you can enable the USB HID KB feature by scanning the barcode below Then...

Page 10: ...y Keyboard Types Keyboard layouts vary from country to country The default setting is 1 U S keyboard 1 U S default 2 UK 3 Denmark 4 France 5 Finland 6 Turkey_F 7 Italy 8 Norway 9 Albania 10 Belgium 11...

Page 11: ...11 13 Croatia 14 Czech 15 Dutch 16 Estonia 17 Germany 18 Greek 19 Hungary 20 Irish 21 Latvia 22 Lithunnia 23 Macedonia 24 Spain 25 Poland 26 Portugal...

Page 12: ...12 27 Romania 28 Russia 29 Japan...

Page 13: ...l to Lower Case Example When the Convert All to Lower Case feature is enabled barcode data AbC is transmitted as abc 2 8 USB COM Port Emulation If you connect the engine to the Host via a USB connecti...

Page 14: ...using a serial trigger command When in manual trigger mode the scanner scans until a barcode is read or until the hardware trigger is released When in serial mode the scanner scans until a barcode ha...

Page 15: ...pturing image and illumination session Every 3 frame open one illumination When the backlight of cellphone is weak and the reflection is strong please scan mode 1 Cellphone Mode 1 When the backlight o...

Page 16: ...Only Inverse On Inverse and Normal Both On 3 5 Illumination Illumination setting for 51 41 31XX series Illumination level 4 default Illumination level 3 Illumination level 2 Illumination level 1 3 6...

Page 17: ...17 3 7 Beeper Tone Good Read Low Middle High default 3 8 Beeper Duration Good Read Normal default Short 3 9 Beeper Number Good Read 1 default 2 3 4 5 6...

Page 18: ...18 3 10 Barcode Scanning Delay No Delay default Delay 500MS Delay 2000ms 3 11 Ship Image Ship Image...

Page 19: ...19 4 Data Formatting 4 1 General Configuration Add CR Add LF Add CRLF Add TAB...

Page 20: ...exadecimal values of a desired prefix and then scan the Save barcode Refer to Appendix 2 ASCII Table for hexadecimal values of characters Example Set the custom Prefix to ODE 1 Check the hex values of...

Page 21: ...fix and then scan the Save barcode Refer to Appendix 4 ASCII Table for hexadecimal values of characters Example Set the custom Suffix to ODE 1 Check the hex values of ODE in the ASCII Table ODE 4F 44...

Page 22: ...ttings Enable Disable All Symbologies If the Disable All Symbologies feature is enabled the engine will not be able to read any non programming barcodes except the programming barcodes Enable All Symb...

Page 23: ...ximum and the minimum is valid The maximum value and minimum value can be set using Programming Command Please check the programming command guide for the detail Code 128 max length command 020A03 The...

Page 24: ...last one as its check digit used to verify the accuracy of the data Transmit EAN 8 Check Digit default Do Not Transmit EAN 8 Check Digit Add On Code An EAN 8 barcode can be augmented with a two digit...

Page 25: ...d On Code Disable 5 Digit Add On Code default Add On Code Required EAN 8 Add On Code Required EAN 8 Add On Code Not Required default ENA JAN 8 Addenda Separator When this feature is enabled there is a...

Page 26: ...26 Enable ENA JAN 8 Addenda Separator default Disable ENA JAN 8 Addenda Separator UPC...

Page 27: ...ble EAN 13 Enable EAN 13 default Disable EAN 13 Transmit Check Digit Transmit EAN 13 Check Digit default Do Not Transmit EAN 13 Check Digit Add On Code Enable 2 Digit Add On Code Disable 2 Digit Add O...

Page 28: ...between barcode and addenda When this feature is disabled there is no space Enable ENA JAN 13 Addenda Separator default Disable ENA JAN 13 Addenda Separator ISBN Translate When enable this feature an...

Page 29: ...efaults Restore the Factory Defaults of UPC E default Enable Disable UPC E0 E1 Enable UPC E0 default Disable UPC E0 Enable UPC E1 Disable UPC E1 default UPCE0 Check Digit Enable UPC E0 Check Digit def...

Page 30: ...E barcodes that have addenda Enable UPC E0 Required Disable UPC E0 Required default UPCE0 Addenda Separator Enable UPC E0 Separator default Disable UPC E0 Separator UPCE0 Number System The number sys...

Page 31: ...31 UPCE0 Addenda Enable 2 Digit Addenda Disable 2 Digit Addenda default Enable 5 Digit Addenda Disable 5 Digit Addenda default...

Page 32: ...le Disable UPC A Enable UPC A default Disable UPC A UPC A Check Digit Enable UPC A Check Digit default Disable UPC A Check Digit UPC A Addenda Required When required is scanned the scanner will only r...

Page 33: ...digit of UPC symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will be not transmitted Enable UPC A Number System default Disable UPC A Number Sy...

Page 34: ...e minimum is valid The maximum value and minimum value can be set using Programming Command Please check the programming command guide for the detail Interleaved 2 of 5 max length command 020404 The p...

Page 35: ...35 No check Char default Validate and Transmit Validate not Transmit...

Page 36: ...mum and the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Matrix 2 of 5 max length command 020803 The param...

Page 37: ...tween the maximum and the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Industrial 2 of 5 max length comman...

Page 38: ...Code 39 default Enable Disable Code 39 Enable Code 39 default Disable Code 39 Transmit Start Stop Character Transmit Start Stop Character Do not Transmit Start Stop Character default Code 39 Check Ch...

Page 39: ...n the order that the barcodes were read Enable Append Disable Append default Code 39 Full ASCII Enable Code 39 Full ASCII Disable Code 39 Full ASCII default Code 39 Code Page Code 39 code pages define...

Page 40: ...command can be set from min to 48 Code 39 min length command 020307 The parameter of this command can be set from 0 to max Example Set the Barcode Message length of the minimum value is 10 the maximum...

Page 41: ...he minimum is valid The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Coda bar max length command 020206 The parameter...

Page 42: ...42 Transmit Start Stop Character Transmit Start Stop Character Do not Transmit Start Stop Character default Coda bar Check Character No Check Char default Validate and Transmit Validate no Transmit...

Page 43: ...e minimum is valid The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Code 93 max length command 020D03 The parameter of...

Page 44: ...de with append character ex Space character it buffers the data until it reads a Code 93 barcode which does not have append character Then the data is transmitted in the order that the barcodes were r...

Page 45: ...e minimum is valid The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail GS1 128 max length command 020B03 The parameter of...

Page 46: ...the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail MSI max length command 020E04 The parameter of this comm...

Page 47: ...ateType10Transmit ValidateType10 ThenType11CharTransmit ValidateType10 ThenType11CharNoTransmit ValidateType10NoTransmit Validate2Type10NoTransmit default Validate2Type10CharTransmit Validate2Type10Ch...

Page 48: ...of PDF 417 default Enable Disable PDF 417 Enable PDF 417 default Disable PDF 417 Enable Disable Micro PDF 417 Enable Micro PDF 417 Disable Micro PDF 417 default Message Length Message length can be se...

Page 49: ...he detail PDF417 max length command 021F06 The parameter of this command can be set from min to 2750 PDF417 min length command 021F05 The parameter of this command can be set from 1 to max Example Set...

Page 50: ...and the minimum is valid The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail QR max length command 023703 The parameter o...

Page 51: ...arcode with append character ex Space character it buffers the data until it reads a QR barcode which does not have append character Then the data is transmitted in the order that the barcodes were re...

Page 52: ...minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Data Matrix max length command 023603 The parameter of this c...

Page 53: ...imum and the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Maxi Code max length command 023403 The paramete...

Page 54: ...d the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Aztec max length command 023306 The parameter of this c...

Page 55: ...55 Aztec Append Enable Aztec Append default Disable Aztec Append...

Page 56: ...and the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Hanxin max length command 023803 The parameter of thi...

Page 57: ...l Symbologies 5 4 1 China Postal Code Restore Factory Defaults Restore the Factory Defaults of China Postal Code default Enable Disable China Postal Code Enable China Postal Code Disable China Postal...

Page 58: ...58 5 4 2 Telepen Restore Factory Defaults Restore the Factory Defaults of Telepen default Enable Disable Telepen Enable China Telepen Disable China Telepen default...

Page 59: ...d 2 of 5 I0 No parity check I1 Transmit check digit after parity check I3 Do not transmit check digit after parity check ITF 6 I1 Transmit check digit I3 Do not transmit check digit ITF 14 I1 Transmit...

Page 60: ...MOD10 transmit check digit X3 One check digit MOD11 do not transmit check digit ISBN X4 Standard ISBN ISSN X5 Standard ISSN PDF417 L0 Comply with 1994 PDF417 specifications Data Matrix d0 ECC000 ECC1...

Page 61: ...included FNC1 is the 2nd character after the start character Reference ISO IEC 15424 2008 Information technology Automatic identification and data capture techniques Data Carrier Identifiers including...

Page 62: ...ge Return 0e 14 SO Shift Out 0f 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC3 XOFF Device Control 3 14 20 DC4 Device Control 4 15 21 NAK...

Page 63: ...sterisk 2b 43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forward Slash 30 48 0 31 49 1 32 50 2 33 51 3 34 52 4 35 53 5 36 54 6 37 55 7 38 56 8 39 57 9 3a 58 Colon 3b 59 Semi colon 3c 60 Less Th...

Page 64: ...7 87 W 58 88 X 59 89 Y 5a 90 Z 5b 91 Left Opening Bracket 5c 92 Back Slash 5d 93 Right Closing Bracket 5e 94 Caret Circum ex 5f 95 _ Underscore 60 96 Grave Accent 61 97 a 62 98 b 63 99 c 64 100 d 65 1...

Page 65: ...65 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122 z 7b 123 Left Opening Brace 7c 124 Vertical Bar 7d 125 Right Closing Brace 7e 126 Tilde 7f 127 DEL Delete...

Page 66: ...66 6 3 Appendix 3 Digit Barcodes 0 1 2 3 4 5 6 7 8 9 A B C D E F...

Reviews: