45
5.2.12 GS1-128
Restore Factory Defaults
Restore the Factory Defaults of GS1-128 (default)
Enable/Disable GS1-128
Enable GS1-128 (default)
Disable GS1-128
Message Length
Message length can be set to the maximum value, minimum value. The data between the
maximum and the minimum is valid.
The maximum value and minimum value can be set using Programming command.
Please check the programming command guide for the detail.
GS1-128 max length command: 020B03. The parameter of this command can be set from
min to 80.
GS1-128 min length command: 020B02. The parameter of this command can be set from
0 to max.
Example: Set the Barcode Message length of the minimum value is 10; the maximum
value is 25.
Programming command
Max: 020B0325.
Min: 020B0210.
Summary of Contents for MS846
Page 1: ...1 MS846 User s Manual Version 1 0 Unitech 2D Image Scanner...
Page 12: ...12 27 Romania 28 Russia 29 Japan...
Page 19: ...19 4 Data Formatting 4 1 General Configuration Add CR Add LF Add CRLF Add TAB...
Page 26: ...26 Enable ENA JAN 8 Addenda Separator default Disable ENA JAN 8 Addenda Separator UPC...
Page 35: ...35 No check Char default Validate and Transmit Validate not Transmit...
Page 55: ...55 Aztec Append Enable Aztec Append default Disable Aztec Append...
Page 66: ...66 6 3 Appendix 3 Digit Barcodes 0 1 2 3 4 5 6 7 8 9 A B C D E F...