TABLE 4: 

Physical and Electrical Data

Models F2FV / F3FV(T)

060

Blower - Diameter x Width

11 x 10

Motor

HP

1.0

Nominal RPM

1200

Voltage

208 / 230

Amps

Full Load

7.8 / 7.0

Locked Rotor

Filter

1

Type

Disposable or Permanent

Size

22 x 20 x 1

Permanent Type Kit

1PF603BK

Shipping / Operating Weight (lbs.) - FP

160

TABLE 5: 

Conversion Table

KW & MBH Conversions - for Total Power Input Requirement

FOR

208V

OPERATION 

MULTIPLY

240V

TABULATED KW & MBH BY

.751

230V

240V

.918

TABLE 6: 

Electrical Data - 1 Ø - 208/230-1-60

1

Models

Heater

Model

Max. Static

& Min. CFM

Total Heat

2

KW Staging**

KW

MBH

W1 Only

W2 Only

W1 + W2

Static

Tap

208V

240V

208V

240V

208V

240V

208V

240V

208V

240V

F2FV060H06

F3FV060H06T

2HK*6500806B

0.5

1335

5.6

7.5

19.1

25.6

3.8

5.0

5.6

7.5

5.6

7.5

2HK*6501006B

7.5

10.0

25.6

34.1

3.8

5.0

7.5

10.0

7.5

10.0

2HK16501506B

11.3

15.0

38.6

51.2

3.8

5.0

7.5

10.0

11.3

15.0

2HK16502006B

15.0

20.0

51.2

68.3

3.8

5.0

7.5

10.0

15.0

20.0

2HK16502506B

18.8

25.0

64.2

85.3

3.8

5.0

11.3

15.0

18.8

25.0

1. Heat amps shown at 240V represents maximum heater rating.
2. See conversion Table 5.

TABLE 7: 

Electrical Data - 3 Ø - 208/230-3-60

1

Models

Heater

Model

Max. Static

& Min. CFM

Total Heat

2

KW Staging**

KW

MBH

W1 Only

W2 Only

W1 + W2

Static

Tap

208V

240V

208V

240V

208V

240V

208V

240V

208V

240V

F2FV060H06

F3FV060H06T

2HK06501025B

0.5

1335

7.5

10.0

25.6

34.1

3.8

5.0

7.5

10.0

7.5

10.0

2HK06501525B

11.3

15.0

38.8

51.2

3.8

5.0

7.5

10.0

11.3

15.0

1. Heat amps shown at 240V represents maximum heater rating.
2. See conversion Table 5.

TABLE 8: 

Electrical Data - Cooling Only

MODEL

Minimum Circuit 

Ampacity

ALL VOLTAGES

06

Max. O.C.P.

Amps/Type

75

°

C Wire Size - AWG

208V

240V

F2FV060H06

F3FV060H06T

9.7

8.8

15

14

1.

OCP = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse.

Summary of Contents for F2FV060

Page 1: ...s including but not limited to building electrical and mechanical codes TABLE OF CONTENTS SAFETY 1 SPECIFIC SAFETY RULES AND PRECAUTIONS 2 SAFETY REQUIREMENTS 2 GENERAL INFORMATION 2 INSPECTION 2 LIMI...

Page 2: ...INFORMATION This Single Piece Air Handler provides the flexibility for installation in any upflow or horizontal application These versatile models may be used for cooling or heat pump operation with...

Page 3: ...n to remove pan from position 4A if factory installed 3 Position horizontal pan as required in either A or B position locking it into the vertical drain pan as shown 4 Horizontal drain pans have 4 plu...

Page 4: ...THE SIDES AND REAR OF UNIT SUPPORT BRACKET 060 COIL BAFFLE SHOWN IN RIGHT HORIZONTAL POSITION FIGURE 4 Dimensions Duct Sizes SHIPPING BRACKET REMOVE PRIOR TO INSTALLATION 2 SCREWS 10 3 8 J DRAIN CONNE...

Page 5: ...size filter Standard 1 size permanent or throw away filter may be used or permanent washable filters are available using model num ber 1PF603BK only See Table 4 for filter size SUSPENSION KITS A suspe...

Page 6: ...fitting hand tight and turn an additional 1 8 turn to seal NOTE This procedure should be done within 2 minutes to keep air and contaminates from entering the coil If the orifice cannot be replaced an...

Page 7: ...y with local and national electrical code requirements Read and heed all unit caution labels NOTE It is possible to vary the amount of electric heat turned on during the defrost cycle of a heat pump S...

Page 8: ...d Remove for Heat Pump for heat pump operation See Figure 12 To Set Electric Heat CFM The blower speed required for the Electric Heat is different than cooling Refer to the label in the bag attached t...

Page 9: ...240V F2FV060H06 F3FV060H06T 2HK 6500806B 0 5 1335 5 6 7 5 19 1 25 6 3 8 5 0 5 6 7 5 5 6 7 5 2HK 6501006B 7 5 10 0 25 6 34 1 3 8 5 0 7 5 10 0 7 5 10 0 2HK16501506B 11 3 15 0 38 6 51 2 3 8 5 0 7 5 10 0...

Page 10: ...60 8 6 2HK06501525B 48 6 52 9 50 60 8 6 1 May be 0 or 1 No Breaker or Breaker 2 O C P Over Current Protection device must be HACR type Circuit Breaker or Time Delay fuse TABLE 11 Electrical Data for...

Page 11: ...HEAT 3 4 THERMOSTAT OUTDOOR UNIT DEFROST CONTROL GND SCREW TERMINAL NOT AVAILABLE ON ALL THERMOSTATS IMPORTANT NOTE HEAT PUMP JUMPER ON THE CFM SELECTION BOARD MUST BE REMOVED WHEN AIR HANDLER IS USED...

Page 12: ...nd the local atmospheric conditions Clean filters keep unit efficiency high COIL CLEANING If the coil needs to be cleaned or replaced it should be washed with Calgon coilclean mix one part Coilclean t...

Reviews: