![Unisight TZHEF04 Series User Manual Download Page 64](http://html1.mh-extra.com/html/unisight/tzhef04-series/tzhef04-series_user-manual_3934554064.webp)
Digital Video Network Surveillance System
Unisight Digital Technologies, Inc
64
“Delete” button, you can delete this preset number.
After deleting, press “Return” button to “PTZ” menu. In “PTZ” menu, press
“Confirm” button to save all modification.
Please make sure the PTZ you are using can support preset function.
Sequence setup
In “PTZ” menu, press “Setup” button on the right side of “Sequence No” item,
you can enter “Sequence” setup menu: Shown as Fig.5.33 below
Fig. 5.33 PTZ sequence setup
In “Sequence” setup menu, first input the sequence number. The sequence is
among 1 --- 16. Each sequence is made up of cruise points, and each cruise point
includes preset number, dwell time and dwell speed. Dwell time is the time staying at
that preset number. Dwell speed is the speed that PTZ is moved to that preset number.
Press “Add” button to add one cruise point.
Press “Confirm” button to save the cruise point into the sequence.
After you finish setup the sequence number, press “StartSeq” to check the current
sequence. Press “Stop” button to stop checking.
You can delete cruise points in one sequence.
After you finish sequence setup, press “Return” button back to “PTZ” menu. In
“PTZ” menu, press “Confirm” button to save the modification.
Please make sure the PTZ you are using can support sequence function.
Cruise setup