Digital Network Video Surveillance System
One-button Backup
Please connect the backup device to the USB port in the front panel. Click the F1 button in the remote
control, the DVR can automatically backup the record file(s) of current day to the backup device.
PTZ Control and Color Setup
Note:
All the operations here are based on PELCOD protocol. For other protocols, there might be a
little difference.
Cable Connection
Please follow the procedures below to go on cable connection
Connect the dome RS485 port to DVR 485 port.
Connect dome video output cable to DVR video input port.
Connect power adapter to the dome.
PTZ Setup
Note:
The camera video should be in the current screen. Before setup, please check the following
connections are right:
PTZ and decoder connection is right. Decoder address setup is right.
Decoder A (B) line connects with DVR A (B) line.
Boot up the DVR, input user name and password.
In the main menu, click setting, and then click Pan/Tilt Control button. The interface is shown as in
X322H322H322H292H292H292H299H
Figure 4-29
X
. Here you can set the following items:
Channel: select the current camera channel.
Protocol: select corresponding PTZ protocol(such as PELCOD)
Address: default address is 1.
Baud rate: select corresponding baud rate. Default value is 9600.
Data bits: select corresponding data bits. Default value is 8.
Stop bits: select corresponding stop bits. Default value is 1.
Parity: there are three options: odd/even/none. Default setup is none.
Unisight Digital Technologies, Inc.