Maintenance Mode
Parameters Lowest
Value
Highest
Value
Option 1
Option 2
Default
Value
Meaning
KEY DN
0
255
---
---
0
Number of times the
Stop Switch was down
or disconnected on
power-up since last
reset.
NO RPM
0
255
---
---
0
Number of times the
display did not detect
a RMP signal.
SP CNG
0
255
---
---
0
Number of times a
sudden change in
speed was detected
EL STL
0
255
---
---
0
Number of times an
elevation stall was
detected.
EL RNG
0
255
---
---
0
Number of counts per
RPM Sensor
revolution.
EL LOST
0
255
---
---
0
Number of times no
elevation was
detected.
ELZERO
0
255
---
---
240
Represents the incline
number for 0%.
EL MAX
0
255
---
---
57
Represents the incline
number for 15%.
LSTERR
0
25
---
---
0
Indicates what display
code appeared last.
18 = NO STO
19 = KEYDN
20 = NO RPM
21 = SP CNG
22 = EL STL
23 = EL RNG
24 = EL LOST
LSTELV
0
255
---
---
0
Displays the target
elevation prior to the
display code.
LSTPOT
0
255
---
---
0
Displays the incline
number prior to the
display code.