Maintenance Mode
Parameters Lowest
Value
Highest
Value
Option 1
Option 2
Default
Value
Meaning
HRT CON
---
---
ON
OFF
OFF
OFF= Heart Control
disable
ON= Heart Control
enabled
HRT
---
---
CNT DN
POLAR
CONTACT
BOTH
CNT DN
POLAR
CONTACT
BOTH
CNT DN
CNT DN= Manual
countdown heart rate
POLAR, CONTACT or
BOTH (Polar &
Contact)
10 REV
22.0
74.0
30.7 = For
110v units.
35.8 = For
220v units
29.1
Inches of running belt
travel for 10 flywheel
revolutions, measured
in inches.
1.8” pulley:30.7 (110v)
2.1”pulley:35.8(220v)
CNT/REV
1
255
31 =
Magnetic
RPM Sensor
125 =
Optical
Sensor
31
Number of counts per
RPM Sensor
revolution.
MN PWM
2
50
---
---
30
Minimum PWM to
obtain minimum
speed, automatically
done.
1/2 PWM
25
170
---
---
130
1/2 Maximum PWM to
obtain 1/2 maximum
speed, automatically
done.
MX PWM
86
255
---
---
230
Maximum PWM to
obtain maximum
speed, automatically
done.
DATE
1.00
12.99
---
---
1.96
Treadmill
manufacturing date.
NO STO
0
255
---
---
0
Number of times the
Stop Switch was down
or disconnected on
power-up since last
reset.
3.5