Emoji Roller GMP Manual
09/17/2022
32
Display
Possible Cause
Recommended action
Motor is faulty.
Replace Motor.
Motor fuse is broken.
Replace motor fuse.
Fuse is broken.
Replace fuse.
(P1 machine replace F9 fuse.
P2 machine replace F21 fuse)
Motor drive board J4
connector loose during
transport.
Check and reconnect the
loose connector of Motor
drive board.
Motor drive board is faulty.
Replace Motor drive board.
Ball jam.
Motor control drive board
is faulty.
Replace Motor control drive
board.
Cable became loose during
transport.
Check and reconnect the
loose cables of U3
mainboard.
U3 mainboard is faulty.
Replace U3 mainboard.
Fuse is broken.
Replace fuse.
(P1 machine replace F8 fuse.
P2 machine replace F20 fuse)