Page
7
SunFrame
Unirac Code-Compliant Installation Manual
R
1411 Broadway Boulevard NE
Albuquerque NM 87102-1545 USA
2
10
-21.0
-25.9
-31.4
-37.3
-43.8
-50.8
-58.3
-74.9
2
20
-20.6
-25.5
-30.8
-36.7
-43.0
-49.9
-57.3
-73.6
2
50
-20.1
-24.9
-30.1
-35.8
-42.0
-48.7
-55.9
-71.8
2
100
-19.8
-24.4
-29.5
-35.1
-41.2
-47.8
-54.9
-70.5
3
10
-34.6
-42.7
-51.6
-61.5
-72.1
-83.7
-96.0 -123.4
3
20
-27.1
-33.5
-40.5
-48.3
-56.6
-65.7
-75.4
-96.8
3
50
-17.3
-21.4
-25.9
-30.8
-36.1
-41.9
-48.1
-61.8
3
100
-10.0
-12.2
-14.8
-17.6
-20.6
-23.9
-27.4
-35.2
2
10
-27.2
-33.5
-40.6
-48.3
-56.7
-65.7
-75.5
-96.9
2
20
-27.2
-33.5
-40.6
-48.3
-56.7
-65.7
-75.5
-96.9
2
50
-27.2
-33.5
-40.6
-48.3
-56.7
-65.7
-75.5
-96.9
2
100
-27.2
-33.5
-40.6
-48.3
-56.7
-65.7
-75.5
-96.9
3
10 -45.7 -56.4 -68.3 -81.2 -95.3 -110.6 -126.9 -163.0
3
20
-41.2
-50.9
-61.6
-73.3
-86.0
-99.8 -114.5 -147.1
3
50
-35.3
-43.6
-52.8
-62.8
-73.7
-85.5
-98.1 -126.1
3
100
-30.9
-38.1
-46.1
-54.9
-64.4
-74.7
-85.8 -110.1
2
10
-24.7
-30.5
-36.9
-43.9
-51.5
-59.8
-68.6
-88.1
2
20
-24.0
-29.6
-35.8
-42.6
-50.0
-58.0
-66.5
-85.5
2
50
-23.0
-28.4
-34.3
-40.8
-47.9
-55.6
-63.8
-82.0
2
100
-22.2
-27.4
-33.2
-39.5
-46.4
-53.8
-61.7
-79.3
3
10
-24.7
-30.5
-36.9
-43.9
-51.5
-59.8
-68.6
-88.1
3
20
-24.0
-29.6
-35.8
-42.6
-50.0
-58.0
-66.5
-85.5
3
50
-23.0
-28.4
-34.3
-40.8
-47.9
-55.6
-63.8
-82.0
3
100
-22.2
-27.4
-33.2
-39.5
-46.4
-53.8
-61.7
-79.3
90
100
110
120
130
140
150
170
Table 3. p
net30
(psf)
Roof Overhang
Source: ASCE/SEI 7-05, Minimum Design Loads for Buildings and Other Structures, Chapter 6, p. 44.
Roof 27 to 45 degr
ees
Roof 7 to 27 degr
ees
Roof 0 to 7 degr
ees
Basic Wind Speed, V (mph)
Effective
Wind Area
(sf)
Zone
Step 5: Determine the Topographic Factor,
K
zt
:
For the purposes of this code compliance document, the
Topographic Factor
,
K
zt
, is taken as equal to one (1), meaning,
the installation is on level ground (less than 10% slope) . If the
installation is not on level ground, please consult ASCE 7-05,
Section 6 .5 .7 and the local building authority to determine the
Topographic Factor
.
Step 6: Determine
Exposure Category (B, C, D):
Determine the
Exposure Category
by using the following
definitions for Surface Roughness Categories .
The
ASCE/SEI 7-05*
defines wind exposure categories as
follows:
S
urface
r
oughneSS
b
is urban and suburban areas,
wooded areas, or other terrain with numerous closely
spaced obstructions having the size of single family
dwellings .
S
urface
r
oughneSS
c
has open terrain with scat-
tered obstructions having heights generally less than
30 feet . This category includes flat open country,
grasslands, and all water surfaces in hurricane prone
regions .
S
urface
r
oughneSS
d
has flat, unobstructed areas
and water surfaces outside hurricane prone regions .
This category includes smooth mud flats, salt flats, and
unbroken ice .
Also see ASCE 7-05 pages 287-291 for further explanation and
explanatory photographs, and confirm your selection with the
local building authority .