to all LP connections. The appearance of bubbles indicates a leak and should
be repaired
immediately
by a qualified serviceman.
W
ARNING
–
D
O NOT USE FLAME TO CHECK FOR GAS LEAKS
Check burner flame for proper appearance. The flame should be light blue with no
yellow at the tip.
See figure #6
•
The LP gas pressure should be checked and the main regulator readjusted if
pressure is incorrect. The correct operating pressure is 11” W.C. (water
column).
•
Inspect the flue baffle, it should be clean and free of soot. Any soot formation
indicates improper functioning of the burner. The flue and burner both
require cleaning in the following manner:
o
Remove cover from the burner housing.
o
Disconnect the wire from the spark electrode
o
Remove the burner
o
Remove the wire and flue baffle from the top of flue tube. Clean the
flue from the top using a flue brush,
be sure to cover the burner if
remaining intact
to eliminate dirt falling into burner. Blowing