U G P 1 0
7
4.
Adjust the thermostat knob to desired temperature setting after 4 to 8
hours of operation.
“Shut Down” Procedure
1.
Turn knob
C
to Gas “Off” position.
Note: If using CO-Monitor, the monitor must be hooked up and be reset with
the battery installed for the flame to stay on – Refer to Chapter 6
CONTROLS –
See Fig 5. for description of controls
Figure #5
Thermostat
The refrigerator cooling temperature is controlled by a combination thermostat that
can be adjusted by turning knob
B
to different settings to maintain the desired
refrigerator temperature. Knob
C
also incorporates a safety device which automatically
shuts off the supply of gas if the flame goes out. The piezo electric igniter discharges
sparks onto the burner when the button is pushed.
See Figure #5
1.
“DEF” Defrost Setting on the Gas Thermostat:
In gas operation, the thermostat
closes its main valve and the burner runs continuously at the bypass rate or pilot
flame.(turn fully counter clockwise)
2.
“MAX” Setting of the Thermostat:
In gas operation, the thermostat allows the
burner to remain on high flame continuously. (turn clockwise)
3. The thermostat can be adjusted between “Max” and “Defrost” to obtain the desired
fridge temperature.
When the thermostat reaches the set temperature, it will reduce the burner back to
bypass operation.
1
2
3
4