Set Up Menu
Exit the service menu by pressing the menu button
Depth Calibration
Set Level
Bath tubs vary in depth and this function permits depths of more than 100% to be
set and run for depth calibration purposes. The depth value can go up to 255%. If
this depth is insufficient one needs to take interim 100% bath calibration steps until
the correct full bath depth is reached.
Filling does not stop automatically and can cause damage unless used correctly.
0% - bath calibration
The easiest and fastest way for 0% bath calibration is by pouring water into the bath
tub with the drain closed until the water fills the cavity of the waste completely and
becomes level with the bottom of the bath tub. When the water is level with the
bottom of the bath tub let it settle for 1 minute then select SET 0% in the SERVICE
MENU and press
to store the value.