OPERATING MANUAL

 

 

INVO Series 

 

5KVA INVERTER / CHARGER 

INVC4850H – 48V Battery 
INVC9650H – 96V Battery 

 

 

 

 

 

 

 

 

 

 

WWW.UNIPOWERCORP.COM

 

 

 

 

 

 

Manual No. INVO-1 

© 2011 UNIPOWER Corp. 

08/11  invo-.man 

All Rights Reserved 

Summary of Contents for INVC4850H

Page 1: ...r corp com EUROPE ParklandBusinessCentre ChartwellRoad Lancing BN158UE ENGLAND Tel 44 0 1903768200 Fax 44 0 1903764540 telecom unipower europe com OPERATING MANUAL INVO Series 5KVA INVERTER CHARGER IN...

Page 2: ...INVO SERIES INVERTER CHARGER INSTALLATION OPERATING MANUAL Manual No INVO 1 Page 2 08 11 invo man...

Page 3: ...al Precautions 5 INSTALLATION 6 Unpacking and Inspection 6 Basic Configuration 6 Batteries 7 Battery Cable Size 7 DC Disconnect and Over Current Protection 8 Battery Cable Connection 8 AC Cable Size 9...

Page 4: ...ce risk of injury charge only deep cycle lead acid type rechargeable batteries Other types of batteries may burst causing personal injury and damage 3 Do not expose the inverter charger to rain snow o...

Page 5: ...Lug should be bonded to the grounding system at ONLY one in the system All installations should comply with all national and local codes and ordinances Personal Precautions 1 Someone should be within...

Page 6: ...below are present Please call customer service if any items are missing The Inverter Charger 1 DC red cable 1 DC black cable 1 User s manual this document Basic Configuration The following illustrati...

Page 7: ...be held responsible Batteries The INVO inverter charger supports either a 48 volt or a 96 volt battery bank depending on the model Please refer to figure 2 for wiring the battery correctly Before proc...

Page 8: ...he inverter charger s battery terminal Tighten the M8 screw to 5 8 Nm Do not place anything between the flat part of the Backup terminal and the battery cable ring terminal or overheating may occur DO...

Page 9: ...terminal block is used to hardwire the AC input AC output and ground The National Electrical Code requires that an external disconnect switch be used in the AC input wiring circuit The AC breakers in...

Page 10: ...terminal marked AC Line output following the wiring guide inside the compartment Connect the AC neutral out to the AC neutral out terminal Torque the wires into the terminal block 5 Use the two M3 sc...

Page 11: ...above 42V for the INV5048H and 82V for the INV5096H Configuration Switch On the right of panel are the 4 configuration switches which setup the inverter charger operation parameters See table 3 for d...

Page 12: ...on the battery voltage level Charging Indicator When line mode and input within range the charging symbol will show up And battery capacity segment will roll flashing in turn basing on capacity Charge...

Page 13: ...is cycle the batteries are charged at a constant current 2 Constant Voltage Stage During this cycle the batteries are held at a constant voltage 14 1V per 12V block for AGM GEL 14 6V per 12V block for...

Page 14: ...nnect 280Vac High Line Re connect 270Vac Max AC Input Voltage 300Vac rms Nominal Input Frequency 50Hz 60Hz Auto detect Low Line Frequency Disconnect 40 1Hz Low Line Frequency Reconnect 42 1Hz High Lin...

Page 15: ...put Short Circuit Protection Current limit Fault after 4 cycles max Bypass Breaker Size 40A Nominal DC Input Voltage 48V 96V Min DC start voltage 40V 80V Low DC Alarm 42 0 1 2Vdc 84 0 2 4Vdc Low DC Al...

Page 16: ...0A setting 10A 95 175V gen wide only 20A 175 275V 20A setting 10A 175 275v 10A setting Battery initial voltage sps setup 35Vdc 70Vdc Charger Short Circuit Protection Inverter charger shuts down automa...

Page 17: ...own Beep continuous Auto Mains is normal 1 Over Charge Protection Line DC Voltage High DC input Shut down Beep continuous Manual 1 Over Voltage Protection Standby DC Voltage High DC input Shut down Be...

Page 18: ...rify that the load matches the capability specified 2 Output short circuit 2 Check wiring or remove abnormal load 3 Over temp 3 Remove any obstruction in front of airflow inlet 4 Over charger 4 Restar...