![Uniphone UD-60 Basic Installation & Programming Manual Download Page 31](http://html1.mh-extra.com/html/uniphone/ud-60-basic/ud-60-basic_installation-and-programming-manual_4497009031.webp)
26
Kind 1 (26-38)
Item
Description
Default
Instruction
26
27 Route for auto-grabbing station
0
0: Circulation (First STA – Last STA)
1: From the 1st STA
2: From the last STA
3. Circulation (Last STA – First STA)
Related program: K2 item 73, function no.43
28 Time units of tone break bit
200
164-9999 ms
Related program: K8, K18
29
CO pulse interval between code and code
dialing
233
1-9999 x 3.333 ms
TRK to PBX. It is interval time of "code to
code" when analog CO line is pulse dialing.
30 Route for auto-grabbing trunk line
0
0: Circulating (First CO– Last CO)
1: From the 1st CO line
2: From the last CO line
3. Circulation (Last CO – First CO)
Relative program: K3 Item9,24
31 Programming Password
2656
4 Digits code.
Notice
: DIP SW2 of CPU card must be "ON".
32
33
Restricted/Allowed dialing table for 2nd
class: City call service class
LC2=0: 0 1 2 3 4 5 6 7
01234567
Setting value: 0-8
For outward dialing restriction, match to program
K7 (Restricted/Allowed dialing table)
0-5: Restricted table (Barring Call)
6-8: Allowed table
There are 30 groups of number per table.
Related program: K2 item 39-40
34
Restricted/Allowed dialing table for 3rd
class: National call service class
LC3=0:
1 2 3 4 5
.12345…
35
Restricted/Allowed dialing table for 4th
class: International call service class 1
LC4=0:
2 3 4 5
..2345…
36
Restricted/Allowed dialing table for 5th
class: International call service class 2
LC5=0:
3 4 5
…345…
37
Restricted/Allowed dialing table for 6th
class: International call service class 3
LC6=0:
4 5
….45…
38
Restricted/Allowed dialing table for 7th
class: International call service class 4
LC7=0:
5
…..5…