1.8 Connecting Instruction of Analog Trunk Card and CID card
1.8.1 F8006 4-ports of Trunk Card (TRK-4)
Handle
Bar
LED P2: CO line 1-4
Slot
Connector
GND
CID-4
P2: CO Line port
4
3
2
1
4
3
2
1
4
3
2
1
Check wire
arrange from
here
Connect
2,3 wire to
Trunk Line
Description:
P2 : Connect to trunk line directly.
RJ11-1 - CO1; RJ11-2 - CO2;
RJ11-3- CO3; RJ11-4 - CO4.
MC1,MC2 : Installed the Caller-ID card on.
GND: connect to GND of the MPU card.
LED: It will be ON/OFF repeating when the card is working.