background image

 4

U.B.S. UNION BATTERY SERVICE s.r.l. unipersonale 

Via Alessandro Volta

25015 Desenzano del Garda (Bs) – Italia 

Tel +39 030 9904570 - Fax +39 030 9902207

[email protected]

www.unionbatteryservice.it 

ANOMALIES

 Over discharge. 

 

Procedure: 

  Follow the standard procedure

 Current pulses beyond the allowed limits (see technical data sheet). 

 Procedure: 

  After 10 times in an hour that the battery goes into allarm due to current pulses, the BMS will go into 

  permanent block. 

  To reset it, follow the standard procedure.

 Short circuit. 

 Procedure: 

  The red alarm LED will remain active until the BMS is manually reset. 

  To carry out the manual reset, follow the standard procedure.

 Battery temperature too high (see technical data sheet). 

 Procedure: 

  Disconnect the battery from the load and wait for the temperature to drop. 

  When the red alarm LED go off, check the state of charge of the battery and, if not completely discharged,  

  reconnect it to the load.

 Battery temperature too low (see technical data sheet). 

 Procedure: 

  If the battery temperature is below 0°C it will be possible to discharge the battery (till -15C°) but not  

 

  to charge it. Even if the discharge is not allowd: disconnect the battery form the load and wait for the    

  temperature rising. 

  When the red alarm LED go off, check the state of charge of the battery and, if not completely discharged,  

  reconnect it to the load.

STAND-BY

DISPLAY

If the battery remains on without being used, it will go 

into stand-by mode after 5 hours.

To exit stand-by mode, press the ON/OFF button or press 

the red trigger button (located above the output cables) 

of the charger.

For any information regarding the DISPLAY, contact the 

manufacturer.

STANDARD PROCEDURE FOR THE MANAGEMENT OF THE ALLARM STATUS

When the battery goes into allarm, wait 1 minute for the 

red allarm LED turning off automatically.

When switched off, check the state of charge of the 

battery and, if not completely discharged, it will be 

possibile to use it.

If the automatic shutdown does not occur, disconnect 

the battery from the load and connect it to the "ZHF.LH" 

series compatible charger.

If the charger does not start automatically, press and hold 

the red trigger button (located above the output cables) 

until the red LED on the charger lights up constantly.

If even in this case the charger does not start, it 

means that the battery has a thermal problem, 

so wait for the alarm to automatically switch off. 

The wait could be long: minutes or hours.

Summary of Contents for ZLI012051

Page 1: ... and please safely deal with the disuse battery Don t charge the battery in environments where the temperature is over 50 C or lower than 5 Don t reverse the two electrodes when use the battery Don t penetrate the battery with sharp things Do not disassemble the battery Battery has usage cycle life if its using time is quite little than usual please change your battery Don t weld the battery direc...

Page 2: ...mperatura di scarica consigliata Recommendeddischargetemperature 10 C 45 C Temperaturadicaricamassima Maximumchargetemperature 0 C 60 C Temperatura di carica consigliata Recommendedchargetemperature 5 C 40 C INSTALLATION USE The battery has two cables one red positive and a black one negative with which it will be possible to load and unload it also The battery is supplied without connector availa...

Page 3: ...mple 75 remaining capacity Battery on charge last led level of charge flashing BMS block the battery alarm state Red led 1green flashing led CAUSE OF THE ALLARM STATE Over discharge Current pulses beyond the allowed limits Short circuit Battery temperature too high Battery temperature too low from 100 to 76 from 75 to 51 from 50 to 26 from 25 to 11 from 10 to 0 ...

Page 4: ... it Even if the discharge is not allowd disconnect the battery form the load and wait for the temperature rising When the red alarm LED go off check the state of charge of the battery and if not completely discharged reconnect it to the load STAND BY DISPLAY If the battery remains on without being used it will go into stand by mode after 5 hours To exit stand by mode press the ON OFF button or pre...

Reviews: