4
U.B.S. UNION BATTERY SERVICE s.r.l. unipersonale
Via Alessandro Volta
25015 Desenzano del Garda (Bs) – Italia
Tel +39 030 9904570 - Fax +39 030 9902207
www.unionbatteryservice.it
ANOMALIES
•
Over discharge.
Procedure:
Follow the standard procedure
•
Current pulses beyond the allowed limits (see technical data sheet).
Procedure:
After 10 times in an hour that the battery goes into allarm due to current pulses, the BMS will go into
permanent block.
To reset it, follow the standard procedure.
•
Short circuit.
Procedure:
The red alarm LED will remain active until the BMS is manually reset.
To carry out the manual reset, follow the standard procedure.
•
Battery temperature too high (see technical data sheet).
Procedure:
Disconnect the battery from the load and wait for the temperature to drop.
When the red alarm LED go off, check the state of charge of the battery and, if not completely discharged,
reconnect it to the load.
•
Battery temperature too low (see technical data sheet).
Procedure:
If the battery temperature is below 0°C it will be possible to discharge the battery (till -15C°) but not
to charge it. Even if the discharge is not allowd: disconnect the battery form the load and wait for the
temperature rising.
When the red alarm LED go off, check the state of charge of the battery and, if not completely discharged,
reconnect it to the load.
STAND-BY
DISPLAY
If the battery remains on without being used, it will go
into stand-by mode after 5 hours.
To exit stand-by mode, press the ON/OFF button or press
the red trigger button (located above the output cables)
of the charger.
For any information regarding the DISPLAY, contact the
manufacturer.
STANDARD PROCEDURE FOR THE MANAGEMENT OF THE ALLARM STATUS
When the battery goes into allarm, wait 1 minute for the
red allarm LED turning off automatically.
When switched off, check the state of charge of the
battery and, if not completely discharged, it will be
possibile to use it.
If the automatic shutdown does not occur, disconnect
the battery from the load and connect it to the "ZHF.LH"
series compatible charger.
If the charger does not start automatically, press and hold
the red trigger button (located above the output cables)
until the red LED on the charger lights up constantly.
If even in this case the charger does not start, it
means that the battery has a thermal problem,
so wait for the alarm to automatically switch off.
The wait could be long: minutes or hours.