INSTALLATION MANUAL UNIMI-1BASE ECO PLASTIC
TM
Copyright © 2021 Unimi Solutions AB
Reg pat: EP2668063B
US9376831B2
•
The Unimi-1Base ECO Plastic
TM
foundation is designed for anchoring of EV charging stations in
the ground, predominantly in the outdoor public environment.
•
This installation manual serves as guidelines and function alongside any local building codes.
If in conflict, the local building codes supersede these instructions.
•
The foundation is equipped with 4x110 mm (4 inch) cable conduit inlets positioned in 90-
degree angles from one another allowing easy multiple cable entry. Unused entry holes shall
be covered with the supplied plastic conduit covers.
•
The foundation needs to be placed in a cavity large enough so that the excavated ground
masses can be trampled/vibrated both underneath and on the sides of the foundation. Ensure
that the masses are packed thoroughly so that they fill the compartments of the foundation
ensuring a stable installation result.
•
Recommended min cavity dimensions are 800x800x800 mm depending on ground
stomp/vibrator used. (Please refer to foundation specs at the last page of this manual)
•
It is further recommended that the surrounding masses are of self-draining material such as
mixed stone gravel or macadam with packable characteristics.
•
The top of the foundation shall be flush with the final ground surface level, allowing
pedestrians and lighter traffic to pass over it without the foundation constituting a tripping or
driving hazard if the fou
ndation is installed in “dormant” mode with a manhole cover over it
.
(Manhole cover supplied separately)