PART DRAWING

5

???

Before throwing the packaging material out, make sure no part is left inside. If so, take it out and install it.

Use the part listing for check-up and the installation drawing for guidance.

Connecting your device to the compressed air supply

Supply hoses and threaded couplings

Even though your machine needs small amount of air to work properly (about 60 - 115 l.min 

-1

) you must

use the proper size of air hose and couplings (3/8").

Your device requires operational air pressure of 3.5 bar to work properly.

The maximum air pressure must not be greater then 8.2 bar.

Start up

Before using your machine, drop few drops of pneumatic oil into the air supply opening.

Make sure that no dirt may enter the inside of your machine. Use protective plugs to cover inlets and 

outlets when uncoupling the air supply hose.

Ensure proper lubrication during work.

When using your device only for small work loads, it is usually sufficient to drop few drops of oil into the air

supply inlet.

If you plan on performing heavier work, we recommend using automatic lubrication system.

Always use protective goggles during work.

Air pressure

The maximum air pressure must not be greater then 8.2 bar.

WARNING:

Do not overload your machine.

Using higher pressure then 8,6 bar may damage the inner mechanism of your machine and

it will not be covered by the warranty.

Using your machine

Palm nail hammer MSN 120 is fully automatic tool.

It has no start switch. It will start to work when your press the stopper (21) on the nail's head.

Set the pressure according to the used nail size:

Nail dimensions

Air pressure

6d - 8d

3.5 - 5.5 bar

8d - 12d

5.5 - 6.9 bar

12d - 50d

6.9 - 8.2 bar