6.3

CALIBRATING TURBO TEUTON

The tables on pages  26-31 let you easily calculate the distribution in litres/
hectare of the mistblowers with the standard fittings, proceeding as indicated
below:

a)

 Choose the table relevant to the blower group of the mistblower in question

(the main reference is the number of jets)

b)

 Find the distance between the rows of the vegetation and the diameter of

the nozzles used (ceramic plates, TR or TXA).

c)

 In the horizontal strip, choose the working speed and the distribution in

litres/hectare and on the vertical scale find the pressure to use.

d) 

Adjust the pressure to obtain the treatment required.

If the distance between the rows is different from that in the table you can
easily calculate the distribution in proportion: for example with a distance
between the rows of 8 m, divide the figure for the litres/hectare of the distance
between the 4 m rows by half, with a distance between the rows of 2.5 m
double the figure for the distance between the 5 m rows.
The last line of the table indicates the overall delivery of the fan.
If the mistblower is fitted with non-standard nozzles, the spraying tables of the
single nozzles per mistblower are on page 32.
To calculate the distribution in litres/hectare, use the following formula:

Vd = 600 x Q

I x V

where:

Vd

= volume to distribute (L/ha)

Q

= sum of the nozzles delivery (L/min)

I

= distance between the rows (m)

V

= tractor speed (Km/h)

EXAMPLE:
Distance between the rows: 

5 m

Speed: 

6 Km. / h

Working air pressure 30 bar
Fan 

Ø 800

 with 14 standard, high volume nozzles (Ø 1.0)

Q total delivery of the nozzles

 (Tab. 1 page 34)

 2.96x14= 41.44 L/min

Vd = 600 x 41.44 = 829 L/ha

  5 x 6

N.B

. : Depending on the season the vegetation may be more or less luxuriant;

bear this in mind before starting the treatment. If the plants don’t have much
foliage you should diminish the quantity of litres per hectare using lower
pressures or closing one or more jets of the fan.

N.B. to calculate the different ranges it is
sufficient to multiply the value lt/hectare by the
corresponding width indicated in the table and
divide it by the new width.

Example-
In the table: 907lt/ha with row distance 3m.

907x3 = 971 Lt/ha with row distance 2,8m
   2,8

Summary of Contents for TurboTeuton P500

Page 1: ...04 2010 USE AND MAINTENANCE MANUAL MISTBLOWERS TURBOTEUTON MOUNTED MISTBLOWERS serie TURBOTEUTON MAIA TT P Polipo P SuperSpalliera RV GDV Read this manual carefully before use GB...

Page 2: ...NSPORTING AND MOVING THE MACHINE 9 4 3 1 MOUNTED ATOMISERS 9 4 4 TRACTOR COUPLING 10 4 4 1 THREE POINT COUPLING 10 4 4 5 HYDRAULIC CONNECTION TO THE DISTRIBUTORS 10 4 5 CARDAN SHAFT 11 4 6 PUMP 11 4 7...

Page 3: ...NG POLIPO 4 4 8 NOZZLES NARROW ROWS 26 TABLES FOR CALIBRATING POLIPO 4 4 16 NOZZLES NARROW ROWS 26 TABLES FOR CALIBRATING POLIPO 4 4 8 NOZZLES WIDE ROWS OPTIONAL 27 TABLES FOR CALIBRATING POLIPO 4 4 1...

Page 4: ...work speed over that indicated in the spraying tables in the handbook or too high for the conditions of the terrain use of herbicide booms without an auto levelling system or with the auto levelling s...

Page 5: ...with the improper use of the machine by the operator for this purpose danger signs and symbols and prohibitions are applied near some parts of the machine see previous pictograms Key to the symbols 1...

Page 6: ...se only after having carefully read the instructions on the container 2 3 1 REGULATIONS FOR THE USE OF CHEMICAL PRODUCTS Some recommendations for avoiding damage and accidents Keep the machine in a su...

Page 7: ...ese machines are identified by the word washing on the CE plate 2 7 DRIVING ON THE ROAD The towed mistblowers are not specifically designed for road use Nevertheless many models are also available in...

Page 8: ...components for hydraulic and pneumatic transmissions Hydraulics UNI EN ISO 4254 1 June 2006 Agricultural machines Safety Part 1 General requisites ISO 11684 1995 Pictograms general principles 4 INSTR...

Page 9: ...asn t been bent by knocks during transportation 4 3 TRANSPORTING AND MOVING THE MACHINE Every time you have to lift the machine before starting the operation always make sure the lifting gear and the...

Page 10: ...the elevator coupling pins If necessary position the double diameter pins correctly there are also appropriate adapter bushes available c Adjust the length of the third point tie rod correctly so the...

Page 11: ...the pump FIG 7 NEVER USE THE CARDAN TRANSMISSION IF THE FOLLOWING PROTECTIVE COVERS ARE MISSING TRACTOR POWER TAKEOFF PROTECTIVE COVER CARDAN SHAFT PROTECTIVE COVER FIXED PROTECTIVE COVER ON THE PUMP...

Page 12: ...ion regulator G D auxiliary tap can be used for various accessories it is always manual E volumetric pressure valve proportional when present it regulates the spraying pressure The valve automatically...

Page 13: ...djust the corresponding compensator G until you return to the pressure set previously displayed on the manometer open and close the tap of section C and check that the pressure remains constant repeat...

Page 14: ...and after filling stop the pump and put the lever of deviator D back in the working position disconnect pipe T from deviator D b FILLING WITH THE SUCTION FILTER Fig 3 Fig 11 If the 3 way deviator isn...

Page 15: ...for using chemical products are indicated in paragraph 2 2 1 4 12 2PREMIXER ON COVER OPTIONAL Open the cover and pour all of the chemical powder into the filter close the cover and open the supply ta...

Page 16: ...the power takeoff b Check you have filled the circuit washer tank C c Make sure the main control of the pressure regulator is OFF and that all the boom sectors are closed d Turn suction deviator A to...

Page 17: ...to engage the fan rotor gradually This prevents jerky starts due to the inertia of the fan rotor which can have a negative effect on the transmission For the centrifugal clutch to work properly the s...

Page 18: ...way for the configuration of the vegetation All the adjustments are made by hand using knobs and screws When treating particularly wide rows up to 4 m OPTIONAL extendable arms are available The POLIPO...

Page 19: ...4 1 OIL FEED FROM TRACTOR for hydraulic systems Connect the delivery and discharge quick fit coupling to the respective connections respecting the direction of flow The distributor inlet pipe is conne...

Page 20: ...the single jet if it is facing inwards towards the blower group c nozzle second spray when these are pointing towards the outside of the blower group parallel with the non drip valve 6 2 DESCRIPTION...

Page 21: ...the 5 m rows The last line of the table indicates the overall delivery of the fan If the mistblower is fitted with non standard nozzles the spraying tables of the single nozzles per mistblower are on...

Page 22: ...indicated in paragraph 2 2 1 8 1 PROGRAMMED MAINTENANCE TAB N 7 page 33 We recommend using a table of programmed maintenance to follow in time to keep the mistblower in an efficient working condition...

Page 23: ...le from our reseller perform any repairs or contact a specialised workshop During all of the repairs in particular when welding the machine and the circuit must be clean of any residues of chemical pr...

Page 24: ...t and disposal recovery Transport of one s waste to authorised collection centres is allowed exclusively if you are enrolled in the Environmental Management Register 8 7 3 ELECTRICAL AND ELECTRONIC AP...

Page 25: ...1 8 B1606 0015 filter for 18 jet holes 0 8 1002 0110F Ceramic conical nozzle kit Nozzle 0 8 Dif 1 0 Filter 0 8 3400 0400F filter diffuser and seal Nozzle 1 0 Dif 1 0 Filter 0 8 3400 0401F for 18 mm je...

Page 26: ...n 8 getti Lt ha spreading rate table for Turbo Teuton 8 NOZZLES ISO ARANCIO Orange ISO GIALLO Yellow Larghezza di lavoro PRESSIONE bar 5 7 10 12 15 18 20 5 7 10 12 15 18 20 working width 3 5 390 457 5...

Page 27: ...i Lt ha spreading rate table for Turbo Teuton 8 NOZZLES ISO ARANCIO Orange ISO GIALLO Yellow Larghezza di lavoro PRESSIONE bar 5 7 10 12 15 18 20 5 7 10 12 15 18 20 working width 3 5 281 329 398 425 4...

Page 28: ...uton 10 getti Lt ha spreading rate table for Turbo Teuton 10 NOZZLES ISO ARANCIO Orange ISO GIALLO Yellow Larghezza di lavoro PRESSIONE bar 5 7 10 12 15 18 20 5 7 10 12 15 18 20 working width 3 5 486...

Page 29: ...i Lt ha spreading rate table for Turbo Teuton 10 NOZZLES ISO ARANCIO Orange ISO GIALLO Yellow Larghezza di lavoro PRESSIONE bar 5 7 10 12 15 18 20 5 7 10 12 15 18 20 working width 3 5 350 411 494 535...

Page 30: ...on 10 getti Lt ha spreading rate table for Turbo Teuton 10 NOZZLES ISO ARANCIO Orange ISO GIALLO Yellow Larghezza di lavoro PRESSIONE bar 5 7 10 12 15 18 20 5 7 10 12 15 18 20 working width 3 5 350 41...

Page 31: ...urbo Teuton GDC 10 getti Lt ha spreading rate table for Turbo Teuton GDC 10 NOZZLES ISO ARANCIO Orange ISO GIALLO Yellow Larghezza di lavoro PRESSIONE bar 5 7 10 12 15 18 20 5 7 10 12 15 18 20 working...

Page 32: ...ACITY Lt min 5 cone 1 16 1 40 1 90 2 25 2 65 2 90 3 50 direct jet 1 40 1 70 2 50 3 95 4 7 6 00 7 70 8 cone 1 40 1 80 2 60 2 80 3 40 3 65 4 45 direct jet 1 70 2 20 3 40 4 85 6 00 7 60 9 80 10 cone 1 50...

Page 33: ...n the lever correctly Command group isn t at zero pressure Valves and or valve seats Replace or clean suction and delivery worn or dirty The pump doesn t reach the set Valve and or valve seat Replace...

Page 34: ...R GCP 2 ELECTRIC PRES X X X X DISTRIBUTOR POLIPO 4 4 X X X X ACCESSORIES POLIPO 5 5 X X X X SUPER SPALLIERA 4 4 X X X X RV GDC 5 5 X X X SINGLE 18 X X X X NOZZLES DOUBLE 18 X X X X NOZZLE TIPS Ceramic...

Page 35: ...unigreen 35...

Page 36: ...erves the right to make variations or modifications without prior warning via Rinaldi 105 42124 Reggio Emilia ITALY Tel 39 0522 369811 Fax 39 0522 369898 e mail info unigreen spa com internet www unig...

Reviews: