TABLES FOR CALIBRATING ATOMISERS  Ø700-750

TABLES FOR CALIBRATING ATOMISERS

N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width
indicated in the table and divide it by the new width (see chapter 6.3, page 20).

unigreen spa

Tabella erogazione in Litri/ettaro Gr.Ventola Ø700-Ø750  12 getti

Lt./ha spreading rate tab le for Blower Ø700-Ø750  12 NOZZLES

Piastrina ceramica Ø1,0

Piastrina ceramica Ø1,2

Larghezza di lavoro

PRESSIONE bar

10

15

20

25

30

40

50

10

15

20

25

30

40

50

working width

3,5

1291 1474 1680 1863 2029 2309 2537 1737 2126 2434 2709 2983 3429 3771

4

1130 1290 1470 1630 1775 2020 2220 1520 1860 2130 2370 2610 3000 3300

5

904 1032 1176 1304 1420 1616 1776 1216 1488 1704 1896 2088 2400 2640

3

6

753

860

980 1087 1183 1347 1480 1013 1240 1420 1580 1740 2000 2200

7

646

737

840

931 1014 1154 1269 869 1063 1217 1354 1491 1714 1886

3 m.

3,5

969 1106 1260 1397 1521 1731 1903 1303 1594 1826 2031 2237 2571 2829

4

848

968 1103 1223 1331 1515 1665 1140 1395 1598 1778 1958 2250 2475

5

678

774

882

978 1065 1212 1332 912 1116 1278 1422 1566 1800 1980

4

6

565

645

735

815 888 1010 1110 760 930 1065 1185 1305 1500 1650

7

484

553

630

699 761

866

951

651 797

913 1016 1119 1286 1414

4 m.

3,5

775

885 1008 1118 1217 1385 1522 1042 1275 1461 1625 1790 2057 2263

4

678

774

882

978 1065 1212 1332 912 1116 1278 1422 1566 1800 1980

5

542

619

706

782 852

970 1066 730 893 1022 1138 1253 1440 1584

5

6

452

516

588

652 710

808

888

608 744

852

948 1044 1200 1320

7

387

442

504

559 609

693

761

521 638

730

813

895 1029 1131

5 m.

Litri/min.

22,6 25,8 29,4 32,6 35,5 40,4 44,4 30,4 37,2 42,6 47,4 52,2 60,0 66,0

 Tab. 3215/0000F

ug. sing.

1,88 2,15 2,45 2,72 2,96 3,37 3,70 2,53 3,10 3,55 3,95 4,35 5,00 5,50

Velocità Km

/h

s

p

ee

d

Li

tr

i/

ha

Li

tr

i/

ha

Li

tr

i/

ha

Velocità Km

/h

s

p

ee

d

Velocità Km

/h

s

p

ee

d

unigreen spa

Tabella erogazione in Litri/ettaro Gr.Ventola Ø700-Ø750  12 getti

Lt./ha spreading rate tab le for Blower Ø700-Ø750  12NOZZLES

TR80-01 ARANCIO

TR80-015 VERDE

Larghezza di lavoro

PRESSIONE bar

5

7

10

12

15

18

20

5

7

10

12

15

18

20

working width

3,5

349 411 491 537 606 657 691 520 617 731 811 897 989 1040

4

305 360 430 470 530 575 605 455 540 640 710 785 865 910

5

244 288 344 376 424 460 484 364 432 512 568 628 692 728

3

6

203 240 287 313 353 383 403 303 360 427 473 523 577 607

7

174 206 246 269 303 329 346 260 309 366 406 449 494 520

3 m.

3,5

261 309 369 403 454 493 519 390 463 549 609 673 741 780

4

229 270 323 353 398 431 454 341 405 480 533 589 649 683

5

183 216 258 282 318 345 363 273 324 384 426 471 519 546

4

6

153 180 215 235 265 288 303 228 270 320 355 393 433 455

7

131 154 184 201 227 246 259 195 231 274 304 336 371 390

4 m.

3,5

209 247 295 322 363 394 415 312 370 439 487 538 593 624

4

183 216 258 282 318 345 363 273 324 384 426 471 519 546

5

146 173 206 226 254 276 290 218 259 307 341 377 415 437

5

6

122 144 172 188 212 230 242 182 216 256 284 314 346 364

7

105 123 147 161 182 197 207 156 185 219 243 269 297 312

5 m.

Litri/min.

6,1

7,2

8,6

9,4

10,6 11,5 12,1

9,1

10,8 12,8 14,2 15,7 17,3 18,2

 Tab. 3215/0000F

ug. sing.

0,51 0,60 0,72 0,78 0,88 0,96 1,01

0,76 0,90 1,07 1,18 1,31 1,44 1,52

Velocità Km/h

s

p

eed

Litri/ha

Litri/ha

Litri/ha

Velocità Km/h

s

p

eed

Velocità Km/h

s

p

eed

Summary of Contents for Mistblowers AP APC

Page 1: ...USE AND MAINTENANCE MANUAL MISTBLOWERS MOUNTED MISTBLOWERS serie EXPO CLIO KAMBA VENUS DEVIL SIRIO EOLO AP Read this manual carefully before use GB 04 2010 ISO Color code...

Page 2: ...OWED ATOMISERS 9 4 4 TRACTOR COUPLING 10 4 4 1 THREE POINT COUPLING 10 4 4 2 HYDRAULIC CONNECTIONTOTHE DISTRIBUTORS 10 4 5 CARDAN SHAFT 11 4 6 PUMP 11 4 7 SUCTION FILTER 11 4 8 PRESSURE REGULATOR 12 4...

Page 3: ...8 7 2 INDICATIONS FOR A SUITABLETREATMENT OF WASTE 23 8 7 3 ELECTRICAL AND ELECTRONIC APPARATUS WASTE EEAW 23 TABLES FOR CALIBRATING ATOMISERS 500 600 25 TABLES FOR CALIBRATING ATOMISERS 600 650 26 TA...

Page 4: ...nd pipes noz zles pressure gauges oil tyres friction material of the clutches Evident cases of negligence include work speed over that indicated in the spraying tables in the handbook or too high for...

Page 5: ...some residual risks associated with the improper use of the machine by the operator for this purpose danger signs and symbols and prohibitions are applied near some parts of the machine see previous...

Page 6: ...roducts license and in any case only after having carefully read the instructions on the container 2 3 1 REGULATIONS FORTHE USE OF CHEMICAL PRODUCTS Some recommendations for avoiding damage and accide...

Page 7: ...machines are identified by the word washing on the CE plate 2 7 DRIVING ON THE ROAD The towed atomisers are not specifically designed for road use Nevertheless many models are also available in the v...

Page 8: ...ts UNI EN 907 Nov 1998 Agricultural and forestry machinery Sprayers and spreaders of liquid fertilizers Safety UNI EN ISO 13849 1 February 2007 Machinery safety Fundamental concepts general design pri...

Page 9: ...where the fan turns hasn t been bent by knocks during transportation 4 3 TRANSPORTING AND MOVING THE MACHINE Every time you have to lift the machine before starting the operation always make sure the...

Page 10: ...ver bumps b Check the diameter of the elevator coupling pins If necessary position the double diameter pins correctly there are also appropriate adapter bushes available c Adjust the length of the thi...

Page 11: ...CTIVE COVER ON THE PUMP SHAFT 4 6 PUMP When using the pump scrupulously observe the instructions in the enclosed handbook supplied by the manufacturer The pump can be identified by the ratings plate o...

Page 12: ...ies it is always manual E volumetric pressure valve proportional when present it regulates the spraying pressure The valve automatically compensates variations in speed within the scope of the same ge...

Page 13: ...e the proportional valve may not be able to compensate the speed variations correctly Adjusting the compensated returns close only one tap of section C position OFF adjust the corresponding compensato...

Page 14: ...antipollution hydroejector mounted as standard on some models then you should proceed as follows put roughly 20 30 L of water in the tank and start the pump remove the cap of ejector E and insert fil...

Page 15: ...be filled with clean water and used to rinse the entire circuit including the suction delivery pump pressure regulator jets and nozzles Thanks to the practical rotary nozzle it also rinses the inside...

Page 16: ...tiplier made accessible through the opening on the side in the rear left part of the machine or at a distance on the right side The lever has 2 or 3 positions depending on the number of gears and the...

Page 17: ...only be performed by qualified personnel respecting the position of the single vanes so as not to vary the dynamic balance of the fan unbalanced blowers can cause rapid wear of the multiplier and the...

Page 18: ...e clutch see the previous paragraph This fan rotor can usually produce a delivery which is much higher with a very high speed airflow Fig 25 The cannon fan is mounted on a thrust block that can be adj...

Page 19: ...etation to be treated Poor quality or worn nozzles have a tendency to create unevenly treated strips The nozzles are produced in various sizes to work with a precise pressure range to create certain t...

Page 20: ...44 829 L ha 5 x 6 N B Depending on the season the vegetation may be more or less luxuriant bear this in mind before starting the treatment If the plants don t have much foliage you should diminish the...

Page 21: ...int the jet at people or animals The jet can cause serious injuries simply due to the mechanical force of the liquid under pressure Never block the spraying lever of the lance in an open position beca...

Page 22: ...level If you notice even a partial blockage of a nozzle proceed as follows drain the pressure and stop the machine dismantle the screw or bayonet ringnuts holding the nozzles clean with a small brush...

Page 23: ...DEMOLITION AND DISPOSAL When the sprayer will be put out of service you should wash it with great care to remove any residues of chemical product follow the instructions in point 4 13 of the present...

Page 24: ...ixing G1 4 jets on 1 2 booms 1805 0034F Clamp kit for fixing G1 4 jets on 1 2 booms M8 F thread 1805 0050F TXA80 005 Lilac 3400 0611F ISO nozzle TXA80 067 Olive 3400 0612F ceramic conical TXA80 01 Ora...

Page 25: ...07 346 425 487 542 597 686 754 5 m Litri min 15 0 17 2 19 6 21 8 23 7 27 0 29 6 20 2 24 8 28 4 31 6 34 8 40 0 44 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 10 3 55 3 95 4 35 5...

Page 26: ...20 466 507 578 634 434 531 609 677 746 857 943 5 m Litri min 18 8 21 5 24 5 27 2 29 6 33 7 37 0 25 3 31 0 35 5 39 5 43 5 50 0 55 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 10 3...

Page 27: ...7 387 442 504 559 609 693 761 521 638 730 813 895 1029 1131 5 m Litri min 22 6 25 8 29 4 32 6 35 5 40 4 44 4 30 4 37 2 42 6 47 4 52 2 60 0 66 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 7...

Page 28: ...490 544 591 674 740 506 620 710 790 870 1000 1100 6 m Litri min 26 3 30 1 34 3 38 1 41 4 47 2 51 8 35 4 43 4 49 7 55 3 60 9 70 0 77 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 1...

Page 29: ...7 430 491 560 621 677 770 846 579 709 811 903 994 1143 1257 6 m Litri min 30 1 34 4 39 2 43 5 47 4 53 9 59 2 40 5 49 6 56 8 63 2 69 6 80 0 88 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 7...

Page 30: ...4 m Litri min 10 6 12 6 15 0 16 5 18 3 20 2 21 3 21 4 25 3 30 4 33 3 37 2 40 7 43 0 Tab 3215 0000F ug sing 0 76 0 9 1 07 1 18 1 31 1 44 1 52 1 53 1 81 2 17 2 38 2 66 2 91 3 07 14 GETTI Velocit Km h s...

Page 31: ...5 205 253 291 323 356 413 468 343 419 485 544 592 683 768 18 6 171 211 242 269 297 344 390 286 349 404 453 493 569 640 7 147 181 208 231 254 295 334 245 299 347 389 423 488 549 18 m Litri min 31 38 4...

Page 32: ...17 579 631 730 910 5 269 328 380 426 463 534 601 292 359 413 463 505 584 728 23 6 224 273 317 355 386 445 501 243 299 344 386 421 487 607 7 192 234 271 304 331 382 429 209 256 295 331 361 417 520 23 m...

Page 33: ...7 387 434 473 548 683 5 201 246 285 319 347 401 451 219 269 310 347 379 438 546 23 6 168 205 237 266 290 334 376 183 224 258 290 316 365 455 7 144 176 203 228 248 286 322 157 192 221 248 271 313 390 2...

Page 34: ...1 0 70 1 01 1 52 2 07 3 07 4 08 5 09 Code 3400 0611F 3400 0612F 3400 0613F 3400 0614F 3400 0615F 3400 0616F 3400 0617F TAB 3 ISO TABLE OF DELIVERY IN LITRES MIN MEDIUM AND HIGHVOLUME 18 CONICAL NOZZLE...

Page 35: ...one 3 40 4 40 6 20 6 80 8 10 9 20 11 2 direct jet 4 10 5 40 8 30 11 8 15 1 19 1 24 6 TABLE 4 TABLE 4 5 TABLES OF DELIVERY OF NOZZLES FOR HAND LANCES TABLE OF DELIVERY IN LITRES MIN OFTHE CONICAL NOZZL...

Page 36: ...n the lever correctly Command group isn t at zero pressure Valves and or valve seats Replace or clean suction and delivery worn or dirty The pump doesn t reach the set Valve and or valve seat Replace...

Page 37: ...X X X X X X X X X X REGULATOR RVA 2 4 5 WAY X X X X X X X X X X X X X X X X X X RM 40 S X X X X X X X X X X X X X GCPElectric X X X X X X X JETS SINGLENON DRIP X X X X X X X X X X X X X X X X X X DOUB...

Page 38: ...X X X X X X X X REVERBERI AR 1064 1053 X PRESSURE GCP RVA X X X X X X X X X X X X X REGULATOR ORION Comet X X X X X X X X X X X X X GCP ELECTRIC X X X X X X X X X X X X X JETS SINGLENON DRIP X X X X X...

Page 39: ...5 1203 X X X X BHA 160 X X X PRESSURE RVA X X X X X X X X REGULATOR ORION Comet X X X X X X GCPELECTRIC X X X X X X JETS P39 X X SINGLENON DRIP X X X X X X X X DOUBLENON DRIP X X X X X X X X TYREMFC X...

Page 40: ...erves the right to make variations or modifications without prior warning via Rinaldi 105 42124 Reggio Emilia ITALY Tel 39 0522 369811 Fax 39 0522 369898 e mail info unigreen spa com internet www unig...

Reviews: