Unigreen Mistblowers AP APC Use And Maintenance Manual Download Page 25

unigreen  

25

TABLES FOR CALIBRATING ATOMISERS  Ø500-600

TABLES FOR CALIBRATING ATOMISERS

N.B. to calculate the different ranges it is sufficient to multiply the value lt/hectare by the corresponding width
indicated in the table and divide it by the new width (see chapter 6.3, page 20).

unigreen spa

Tabella erogazione in Litri/ettaro Gr.Ventola Ø500-Ø600 8 getti

Lt./ha spreading rate tab le for Blower Ø500-Ø600 8 NOZZLES

Piastrina ceramica Ø1,0

Piastrina ceramica Ø1,2

Larghezza di lavoro

PRESSIONE bar

10

15

20

25

30

40

50

10

15

20

25

30

40

50

working width

3,5

857 983 1120 1246 1354 1543 1691 1154 1417 1623 1806 1989 2286 2514

4

750 860 980 1090 1185 1350 1480 1010 1240 1420 1580 1740 2000 2200

5

600 688 784 872 948 1080 1184 808 992 1136 1264 1392 1600 1760

3

6

500 573 653 727 790 900 987 673 827 947 1053 1160 1333 1467

7

429 491 560 623 677 771 846 577 709 811 903 994 1143 1257

3 m.

3,5

643 737 840 934 1016 1157 1269 866 1063 1217 1354 1491 1714 1886

4

563 645 735 818 889 1013 1110 758 930 1065 1185 1305 1500 1650

5

450 516 588 654 711 810 888 606 744 852 948 1044 1200 1320

4

6

375 430 490 545 593 675 740 505 620 710 790 870 1000 1100

7

321 369 420 467 508 579 634 433 531 609 677 746 857 943

4 m.

3,5

514 590 672 747 813 926 1015 693 850 974 1083 1193 1371 1509

4

450 516 588 654 711 810 888 606 744 852 948 1044 1200 1320

5

360 413 470 523 569 648 710 485 595 682 758 835 960 1056

5

6

300 344 392 436 474 540 592 404 496 568 632 696 800 880

7

257 295 336 374 406 463 507 346 425 487 542 597 686 754

5 m.

Litri/min.

15,0 17,2 19,6 21,8 23,7 27,0 29,6 20,2 24,8 28,4 31,6 34,8 40,0 44,0

 Tab. 3215/0000F

ug. sing.

1,88 2,15 2,45 2,72 2,96 3,37 3,70 2,53 3,10 3,55 3,95 4,35 5,00 5,50

Velocità Km/h

s

p

eed

Litri/ha

Litri/ha

Litri/ha

Velocità Km/h

s

p

eed

Velocità Km/h

s

p

eed

unigreen spa

Tabella erogazione in Litri/ettaro Gr.Ventola Ø500-Ø600 8 getti

Lt./ha spreading rate tab le for Blower Ø500-Ø600 8 NOZZLES

TR80-01 ARANCIO

TR80-015 VERDE

Larghezza di lavoro

PRESSIONE bar

5

7

10

12

15

18

20

5

7

10

12

15

18

20

working width

3,5

234 274 331 354 400 440 463 349 411 491 537 600 657 697

4

205 240 290 310 350 385 405 305 360 430 470 525 575 610

5

164 192 232 248 280 308 324 244 288 344 376 420 460 488

3

6

137 160 193 207 233 257 270 203 240 287 313 350 383 407

7

117 137 166 177 200 220 231 174 206 246 269 300 329 349

3 m.

3,5

176 206 249 266 300 330 347 261 309 369 403 450 493 523

4

154 180 218 233 263 289 304 229 270 323 353 394 431 458

5

123 144 174 186 210 231 243 183 216 258 282 315 345 366

4

6

103 120 145 155 175 193 203 153 180 215 235 263 288 305

7

88

103 124 133 150 165 174 131 154 184 201 225 246 261

4 m.

3,5

141 165 199 213 240 264 278 209 247 295 322 360 394 418

4

123 144 174 186 210 231 243 183 216 258 282 315 345 366

5

98

115 139 149 168 185 194 146 173 206 226 252 276 293

5

6

82

96

116 124 140 154 162 122 144 172 188 210 230 244

7

70

82

99

106 120 132 139 105 123 147 161 180 197 209

5 m.

Litri/min.

4,1

4,8

5,8

6,2

7,0

7,7

8,1

6,1

7,2

8,6

9,4

10,5 11,5 12,2

 Tab. 3215/0000F

ug. sing.

0,51 0,60 0,72 0,78 0,88 0,96 1,01

0,76 0,90 1,07 1,18 1,31 1,44 1,52

Velocità Km/h

s

p

eed

Litri/ha

Litri/ha

Litri/ha

Velocità Km/h

s

p

eed

Velocità Km/h

s

p

eed

Summary of Contents for Mistblowers AP APC

Page 1: ...USE AND MAINTENANCE MANUAL MISTBLOWERS MOUNTED MISTBLOWERS serie EXPO CLIO KAMBA VENUS DEVIL SIRIO EOLO AP Read this manual carefully before use GB 04 2010 ISO Color code...

Page 2: ...OWED ATOMISERS 9 4 4 TRACTOR COUPLING 10 4 4 1 THREE POINT COUPLING 10 4 4 2 HYDRAULIC CONNECTIONTOTHE DISTRIBUTORS 10 4 5 CARDAN SHAFT 11 4 6 PUMP 11 4 7 SUCTION FILTER 11 4 8 PRESSURE REGULATOR 12 4...

Page 3: ...8 7 2 INDICATIONS FOR A SUITABLETREATMENT OF WASTE 23 8 7 3 ELECTRICAL AND ELECTRONIC APPARATUS WASTE EEAW 23 TABLES FOR CALIBRATING ATOMISERS 500 600 25 TABLES FOR CALIBRATING ATOMISERS 600 650 26 TA...

Page 4: ...nd pipes noz zles pressure gauges oil tyres friction material of the clutches Evident cases of negligence include work speed over that indicated in the spraying tables in the handbook or too high for...

Page 5: ...some residual risks associated with the improper use of the machine by the operator for this purpose danger signs and symbols and prohibitions are applied near some parts of the machine see previous...

Page 6: ...roducts license and in any case only after having carefully read the instructions on the container 2 3 1 REGULATIONS FORTHE USE OF CHEMICAL PRODUCTS Some recommendations for avoiding damage and accide...

Page 7: ...machines are identified by the word washing on the CE plate 2 7 DRIVING ON THE ROAD The towed atomisers are not specifically designed for road use Nevertheless many models are also available in the v...

Page 8: ...ts UNI EN 907 Nov 1998 Agricultural and forestry machinery Sprayers and spreaders of liquid fertilizers Safety UNI EN ISO 13849 1 February 2007 Machinery safety Fundamental concepts general design pri...

Page 9: ...where the fan turns hasn t been bent by knocks during transportation 4 3 TRANSPORTING AND MOVING THE MACHINE Every time you have to lift the machine before starting the operation always make sure the...

Page 10: ...ver bumps b Check the diameter of the elevator coupling pins If necessary position the double diameter pins correctly there are also appropriate adapter bushes available c Adjust the length of the thi...

Page 11: ...CTIVE COVER ON THE PUMP SHAFT 4 6 PUMP When using the pump scrupulously observe the instructions in the enclosed handbook supplied by the manufacturer The pump can be identified by the ratings plate o...

Page 12: ...ies it is always manual E volumetric pressure valve proportional when present it regulates the spraying pressure The valve automatically compensates variations in speed within the scope of the same ge...

Page 13: ...e the proportional valve may not be able to compensate the speed variations correctly Adjusting the compensated returns close only one tap of section C position OFF adjust the corresponding compensato...

Page 14: ...antipollution hydroejector mounted as standard on some models then you should proceed as follows put roughly 20 30 L of water in the tank and start the pump remove the cap of ejector E and insert fil...

Page 15: ...be filled with clean water and used to rinse the entire circuit including the suction delivery pump pressure regulator jets and nozzles Thanks to the practical rotary nozzle it also rinses the inside...

Page 16: ...tiplier made accessible through the opening on the side in the rear left part of the machine or at a distance on the right side The lever has 2 or 3 positions depending on the number of gears and the...

Page 17: ...only be performed by qualified personnel respecting the position of the single vanes so as not to vary the dynamic balance of the fan unbalanced blowers can cause rapid wear of the multiplier and the...

Page 18: ...e clutch see the previous paragraph This fan rotor can usually produce a delivery which is much higher with a very high speed airflow Fig 25 The cannon fan is mounted on a thrust block that can be adj...

Page 19: ...etation to be treated Poor quality or worn nozzles have a tendency to create unevenly treated strips The nozzles are produced in various sizes to work with a precise pressure range to create certain t...

Page 20: ...44 829 L ha 5 x 6 N B Depending on the season the vegetation may be more or less luxuriant bear this in mind before starting the treatment If the plants don t have much foliage you should diminish the...

Page 21: ...int the jet at people or animals The jet can cause serious injuries simply due to the mechanical force of the liquid under pressure Never block the spraying lever of the lance in an open position beca...

Page 22: ...level If you notice even a partial blockage of a nozzle proceed as follows drain the pressure and stop the machine dismantle the screw or bayonet ringnuts holding the nozzles clean with a small brush...

Page 23: ...DEMOLITION AND DISPOSAL When the sprayer will be put out of service you should wash it with great care to remove any residues of chemical product follow the instructions in point 4 13 of the present...

Page 24: ...ixing G1 4 jets on 1 2 booms 1805 0034F Clamp kit for fixing G1 4 jets on 1 2 booms M8 F thread 1805 0050F TXA80 005 Lilac 3400 0611F ISO nozzle TXA80 067 Olive 3400 0612F ceramic conical TXA80 01 Ora...

Page 25: ...07 346 425 487 542 597 686 754 5 m Litri min 15 0 17 2 19 6 21 8 23 7 27 0 29 6 20 2 24 8 28 4 31 6 34 8 40 0 44 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 10 3 55 3 95 4 35 5...

Page 26: ...20 466 507 578 634 434 531 609 677 746 857 943 5 m Litri min 18 8 21 5 24 5 27 2 29 6 33 7 37 0 25 3 31 0 35 5 39 5 43 5 50 0 55 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 10 3...

Page 27: ...7 387 442 504 559 609 693 761 521 638 730 813 895 1029 1131 5 m Litri min 22 6 25 8 29 4 32 6 35 5 40 4 44 4 30 4 37 2 42 6 47 4 52 2 60 0 66 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 7...

Page 28: ...490 544 591 674 740 506 620 710 790 870 1000 1100 6 m Litri min 26 3 30 1 34 3 38 1 41 4 47 2 51 8 35 4 43 4 49 7 55 3 60 9 70 0 77 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 70 2 53 3 1...

Page 29: ...7 430 491 560 621 677 770 846 579 709 811 903 994 1143 1257 6 m Litri min 30 1 34 4 39 2 43 5 47 4 53 9 59 2 40 5 49 6 56 8 63 2 69 6 80 0 88 0 Tab 3215 0000F ug sing 1 88 2 15 2 45 2 72 2 96 3 37 3 7...

Page 30: ...4 m Litri min 10 6 12 6 15 0 16 5 18 3 20 2 21 3 21 4 25 3 30 4 33 3 37 2 40 7 43 0 Tab 3215 0000F ug sing 0 76 0 9 1 07 1 18 1 31 1 44 1 52 1 53 1 81 2 17 2 38 2 66 2 91 3 07 14 GETTI Velocit Km h s...

Page 31: ...5 205 253 291 323 356 413 468 343 419 485 544 592 683 768 18 6 171 211 242 269 297 344 390 286 349 404 453 493 569 640 7 147 181 208 231 254 295 334 245 299 347 389 423 488 549 18 m Litri min 31 38 4...

Page 32: ...17 579 631 730 910 5 269 328 380 426 463 534 601 292 359 413 463 505 584 728 23 6 224 273 317 355 386 445 501 243 299 344 386 421 487 607 7 192 234 271 304 331 382 429 209 256 295 331 361 417 520 23 m...

Page 33: ...7 387 434 473 548 683 5 201 246 285 319 347 401 451 219 269 310 347 379 438 546 23 6 168 205 237 266 290 334 376 183 224 258 290 316 365 455 7 144 176 203 228 248 286 322 157 192 221 248 271 313 390 2...

Page 34: ...1 0 70 1 01 1 52 2 07 3 07 4 08 5 09 Code 3400 0611F 3400 0612F 3400 0613F 3400 0614F 3400 0615F 3400 0616F 3400 0617F TAB 3 ISO TABLE OF DELIVERY IN LITRES MIN MEDIUM AND HIGHVOLUME 18 CONICAL NOZZLE...

Page 35: ...one 3 40 4 40 6 20 6 80 8 10 9 20 11 2 direct jet 4 10 5 40 8 30 11 8 15 1 19 1 24 6 TABLE 4 TABLE 4 5 TABLES OF DELIVERY OF NOZZLES FOR HAND LANCES TABLE OF DELIVERY IN LITRES MIN OFTHE CONICAL NOZZL...

Page 36: ...n the lever correctly Command group isn t at zero pressure Valves and or valve seats Replace or clean suction and delivery worn or dirty The pump doesn t reach the set Valve and or valve seat Replace...

Page 37: ...X X X X X X X X X X REGULATOR RVA 2 4 5 WAY X X X X X X X X X X X X X X X X X X RM 40 S X X X X X X X X X X X X X GCPElectric X X X X X X X JETS SINGLENON DRIP X X X X X X X X X X X X X X X X X X DOUB...

Page 38: ...X X X X X X X X REVERBERI AR 1064 1053 X PRESSURE GCP RVA X X X X X X X X X X X X X REGULATOR ORION Comet X X X X X X X X X X X X X GCP ELECTRIC X X X X X X X X X X X X X JETS SINGLENON DRIP X X X X X...

Page 39: ...5 1203 X X X X BHA 160 X X X PRESSURE RVA X X X X X X X X REGULATOR ORION Comet X X X X X X GCPELECTRIC X X X X X X JETS P39 X X SINGLENON DRIP X X X X X X X X DOUBLENON DRIP X X X X X X X X TYREMFC X...

Page 40: ...erves the right to make variations or modifications without prior warning via Rinaldi 105 42124 Reggio Emilia ITALY Tel 39 0522 369811 Fax 39 0522 369898 e mail info unigreen spa com internet www unig...

Reviews: