C.I.B. UNIGAS
- M03956CR
24
-
Multibloc MB-DLE:
the valve is adjusted by means of the
RP
regulator after slackening the locking screw
VB
by a number of
turns. By unscrewing the regulator
RP
the valve opens, screwing the valve closes. The pressure stabilizer is adjusted by operating
the screw
VS
located under the cover
C
. By screwing down the pressure is increased and by unscrewing it is reduced.
Note:
the
screw
VSB
must be removed only in case of replacemente of the coil.
- Siemens VGD valves group:
remove cap
T
and act on the
VR
adjusting screw to increase or decrease the pressure and conse-
quently the gas rate; screwind
VR
the rate increases, unscrewing it decreases (see next figure).
- Dungs MBC..SE valves group:
act on its pressure governor to increase or decrease the pressure and consequently the gas
rate.
Pressure governor is factory-set. The setting values must be locally adapted to machine conditions. Important! Follow the instruc-
tions carefully!
8
.To adjust the
air flow rate in the high flame stage
, loose the
RA
nut and screw
VRA
as to get the desired air flow rate: moving
the rod
T
towards the air damper shaft, the air damper opens and consequently the air flow rate increases, moving it far from the
shaft the air damper closes and the air flow rate decreases.
Note:
once the procedure is perfomed, be sure that the blocking nut
RA
is fasten.
Go on adjusting the burner according to the model (double-stage, progressive, fully-modulating).
*OOFOTFDITLBOUTDIMàTTFM/P
"MMFOLFZOP
$MÏEFTJYQBOTNÉMFOP
$IJBWFFTBHPOBMFDBWBOS
1
#S
Siemens VGD..
Dungs MBC..SE
VR
T
C
VS
T(VR)
RP
VB
VSB
Dungs Multibloc MB-DLE
VRA
VRA
RA
TR