8
9750/11.
NOTE ON THE BURNER WORKING SERVICE:
for safety reasons, one controlled shutdown must be performed every 24 hours of
continuous operation.
NOTE:
Choosing the nozzle for light oil, consider Hi equal to 10200 kcal/kg.
Country and usefulness gas categories
BURNER TYPE
HTP512A
HTP515A
HTP520A
HTP525A
Output
min
-
max kW
600-4500
770 - 5200
1000 - 6400
2000 - 9750
Fuel
Natural gas
-
Light oil
Gas category
(
see next paragraph
)
Gas rate
min.-max. (Stm
3
/h)
63 - 476
81 - 550
106 - 677
212 - 1032
Gas pressure
(
see Note 2
)
Oil viscosity
cSt
@
40°C
2 - 7.4
Oil density
kg/m
3
840
Oil rate
min.-max. (kg/h)
51 - 379
65 - 438
84 - 540
169 - 822
Power supply
230
V
3~ / 400
V
3N~ 50
Hz
400
V
3N~ 50
Hz
Pump motor
kW
1.1
1.5
1.5
4
Total power consumption
kW
1.6
2
2
4.5
Protection
IP40
Operation
Progressive - Fully modulating
Gas train
50
Ø
Valves
/ Connection
2” / Rp 2
-
Gas train
65
Ø
Valves
/ Connection
2”
1/2
/ DN65
Gas train
80
Ø
Valves / Connection
3” / DN80
Gas train
100
Ø
Valves
/Connection
4” / DN100
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service
*
Intermittent
noise level (sound power level )(**)
dBa, max
80
Note1:
All gas flow rates are referred to Stm
3
/h (1013 mbar absolute pressure, 15 °C temperature) and are valid for G20 gas
(net calorific value H
i
= 34.02 MJ/Stm
3
);
Note2:
Maximum gas pressure = 500mbar (with
Siemens VGD)
Minimum gas pressure = see gas curves.
Note3:
Burners are suitable only for indoor operation with a maximum relative humidity of 80%
GAS
CATEGORY
COUNTRY
I
2H
AT ES GR SE
FI
IE
HU
IS
NO CZ DK GB
IT
PT CY EE
LV
SI
MT SK BG LT RO TR CH
I
2E
LU
PL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I
2E( R ) B
BE
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I
2L
NL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I
2ELL
DE
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I
2Er
FR
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Summary of Contents for HTP90A
Page 33: ...33 Fig 16...
Page 54: ...54...
Page 56: ...56...
Page 57: ...57...
Page 58: ......
Page 59: ......
Page 61: ...LME73 000Ax PME73 831AxBC LME73 831AxBC Service instruction manual M12921CB Rel 1 2 02 2016...
Page 83: ...23...
Page 84: ...Note Specifications and data subject to change Errors and omissions excepted...