PART I: SPECIFICATIONS
7
(*) NOTE ON THE WORKING SERVICE: the control box automatically stops after 24h of continuous working. The control box
immediately starts up, automatically.
BURNER TYPE
HR512A MG..
HR515A MG..
HR520A MG..
HR525A
MG...50
HR525A MG...xx
Output
min. - max. kW
600 - 4.500
770 - 5.200
1000 - 6.400
2000 - 6.700
2000 - 8.000
Fuel
Natural gas - Light oil
Category
(see next paragraph)
Gas rate-
Natural gas
min.- max. (Stm
3
/h)
63 - 476
81 - 550
106 - 677
212 - 709
212 - 847
PressureGas pressure
mbar
(
see Note 2
)
Light oil rate
min.-max. kg/h
50 - 379
65 - 438
84 - 539
168 - 564
168 - 674
Oil viscosity
2 - 7.4 cSt @ 40°C
Oil density
kg/m
3
840
Light oil train inlet pressure
bar max
2
Power supply
230V 3~ / 400V 3N ~ 50Hz
Total power consumption
kW
10.8
13
17
22
22
Electric motor
kW
9.2
11
15
18.5
18.5
Pump motor
kW
1.1
1.5
1.5
3
3
Protection
IP40
Operation
Progressive - Fully modulating
Gas train 50
Valves size / Gas connection
50 / Rp2
50 / Rp2
50 / Rp2
50 / Rp2
Gas train 65
Valves size / Gas connection
65 / DN65
65 / DN65
65 / DN65
-
65 / DN65
Gas train 80
Valves size / Gas connection
80 / DN80
80 / DN80
80 / DN80
-
80 / DN80
Gas train 100
Valves size / Gas connection
100 / DN100
100 / DN100
100 / DN100
-
100 / DN100
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service (*)
Intermitent
BURNER TYPE
HR512A LG..
HR515A LG..
HR520A LG..
HR525A LG...50
HR525A LG...xx
Output
min. - max. kW
600 - 4.500
770 - 5.200
1.000 - 6.400
2.000 - 6.700
2.000 - 8.000
Fuel
L - LPG - Light oil
Category
I
3B/P
LPG rate L-
min.- max. (Stm
3
/h)
22 - 168
29 - 194
37 - 239
75 - 250
75 - 299
PressureGas pressure
mbar
(
see Note 2
)
Light oil rate G-
min.-max. kg/h
51 - 379
65 - 438
84 - 540
169 - 565
169 - 675
Oil viscosity
2 - 7.4 cSt @ 40°C
Oil density
kg/m
3
840
Light oil train inlet pressure
bar max
2
Power supply
230V 3~ / 400V 3N ~ 50Hz
Total power consumption
kW
10.8
13
17
22
22
Electric motor
kW
9.2
11
15
18.5
18.5
Pump motor
kW
1.1
1.5
1.5
3
3
Protection
IP40
Operation
Progressive - Fully modulating
Gas train 50
Valves size / Gas connection
50 / Rp2
50 / Rp2
50 / Rp2
50 / Rp2
Gas train 65
Valves size / Gas connection
65 / DN65
65 / DN65
65 / DN65
-
65 / DN65
Gas train 80
Valves size / Gas connection
80 / DN80
80 / DN80
80 / DN80
-
80 / DN80
Gas train 100
Valves size / Gas connection
100 / DN100
100 / DN100
100 / DN100
-
100 / DN100
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service (*)
Intermitent
Note1:
All gas flow rates are referred to Stm
3
/ h (1.013 mbar absolute pressure, 15 °C temperature) and are valid for G20 gas
(net calorific value H
i
= 34,02 MJ / Stm
3
); for L.P.G. (net calorific value H
i
= 93,5 MJ / Stm
3
)
Note2:
Maximum gas pressure = 360 mbar (with
Dungs MBDLE)
= 500 mbar (with
Siemens VGD or Dungs MultiBloc MBE)
Minimum gas pressure = see gas curves.
Note3:
Burners are suitable only for indoor operation with a maximum relative humidity of 80 %
Summary of Contents for HR92A
Page 45: ...PART III OPERATION 45 Fig 8...
Page 46: ...PART III OPERATION 46...
Page 57: ...Service manual AZL2x LMV2x 3x Burner Management System M12916CD Rev 3 4 03 2023...
Page 64: ...8 Parameters level heating engineer...
Page 106: ...50 ERROR CODE TABLE...
Page 107: ...51...
Page 108: ...52...
Page 109: ...53...
Page 110: ...54...
Page 111: ...55...
Page 112: ...56...
Page 113: ...57...
Page 114: ...58...
Page 115: ...59...
Page 116: ...60...
Page 117: ...61...
Page 118: ...62...
Page 119: ...63...
Page 120: ...64...
Page 125: ......
Page 126: ......
Page 127: ......
Page 129: ......
Page 130: ......
Page 131: ......
Page 132: ......
Page 133: ......
Page 134: ......
Page 135: ......
Page 136: ......
Page 137: ......
Page 138: ......
Page 139: ......
Page 140: ......