Installation and Configuration
work administrator about the MAC address and ask to reserve a fixed IP address via DHCP for
this module.
If NetBIOS is enabled in the network, the address elise-XXXXXXXX can be used when ac-
cessing the module via the network, where XXXXXXXX is the module key number. The mo-
dule key number can be found on the license certificate or on the label on the back of the
module.
Pre-condition: You have access to the network that Wireless Service Gateway WSG is at-
tached to. If not, go to Section 0.0.1, “Access via the Management port”.
1)
Connect the module to the LAN.
2)
Open the web browser and enter the modules IP address or elise-XXXXXXXX, where
XXXXXXXX is the module key number (leading zeros can be excluded). The module key
number can be found on the license certificate or on the label on the back of the module.
3)
on page 27.
Access via the Management port
The management port can be used when Wireless Service Gateway WSG has not got a valid
and unique IP address or when the IP address has been changed, i.e. if Wireless Service Gate-
way WSG has been moved from one network to another. It gives access to the module without
having access to the customer’s network.
Figure 19: Connection via the Management port
The reserved IP address for accessing Wireless Service Gateway WSG via the manage-
ment port is “192.5.36.229”.
A port driver needs to be installed on your PC to get access via the management port. The
driver is located on the module.
The default mode for the management port is Network access but Mass storage is used to get
the required driver for the module. When set to Mass storage, the module will automatically
change to Network access within 10 minutes. By pressing the Mode button twice, the Manage-
ment port toggles from
Network access
to
Mass storage
and the other way around.
The Mass storage mode is only used when the driver, required for accessing the module via the
management port, shall be installed. This is only needed the first time the PC is used for this pur-
pose.
A31003-M2000-J109-01-7631, 30/06/2020