Maintenance
Restarting the Wireless Service Gateway WSG
Restarting the Wireless Service Gateway WSG
Controlled Restart via the Restart Button
When a controlled restart is performed via the Restart button, all ongoing jobs on the module
ends in a controlled way and everything is logged. When the module has shut down the user can
unplug the power cable or wait one minute for the module to automatically start up again. During
startup, there is a delay for three seconds where the user is able to interact with the module and
change to Boot Mode.
• Use a paper clip or similar and press the Restart button and release it within 4 seconds. The
Status LED indicates shutting down with quick flashing blue light
. Before starting
up again, the Status LED will indicate “waiting” for one minute with yellow light
. Here
the power cable can be detached.
If the power cable is not detached the module starts up automatically after one minute. The
Status LED indicates starting up with quick flashing blue light
.
Another form of a controlled restart can be performed via the GUI, but then the module will
immediately start up again without the one minute delay and will not give you enough time to
unplug the power cable.
Forced Restart
Forced restart is used as a last resort when the module does not respond at all.
When a Forced restart is performed, ongoing jobs are not finished (as in a controlled
restart).
The module detects that a forced restart has been made and a voltage restart is performed. Dur-
ing startup, there is a delay for three seconds where the user is able to interact with the module
to change to Boot Mode.
• Use a paper clip or similar and press the Restart button for at least 5 seconds.
The power LED will turn off for a short time (3 seconds) and when it turns on again the Status
LED indicates starting up with quick flashing blue light
.
Reset Back to Factory Default Settings
Resetting the module’s application software back to factory default settings can be done from the
application’s web interface on the Configuration page under Software. Either by switching soft-
ware or reinstalling software and selecting factory default settings.
Factory default settings can also be chosen from the Boot Mode’s web interface when new soft-
ware is installed or when returning to Normal Operation from Boot Mode, see
on page 33.
Network settings (IP address, Host name, etc.) will not be changed.
A31003-M2000-J109-01-7631, 30/06/2020
Wireless Service Gateway WSG, Installation Guide
37