c06.fm
A31003-S2000-R102-16-7620, 02/2016
Provisioning Service, Developer’s Guide
243
Nur für den internen Gebrauch
Phone Parameters - Provisioning
Phone Specific, Hardware Related
device-type
Text.
Max. 50
characters
OpenStage 15;
OpenStage 20E;
OpenStage 20;
OpenStage 40;
OpenStage 60;
OpenStage 80
Sent to the provisioning service to
identify phone variant. Value is read
only. Displayed in the web page ban-
ner. The value is built up during
phone start up, querying hardware
variant.
OpenScape DPIP35 = OpenStage
20, OpenScape DPIP55 G = Open-
Stage 60
gigabit-
ethernet-
enabled
Boolean
true
/
false
Relevant for OpenStage 20/40/60/
80 G / DPIP55G only. Indicates
whether the phone’s network inter-
face is switched to 1Gb/s speed. Val-
ue is read only.
related-
software-type
Text.
Max. 30
characters
Siemens SIP
[SIP] Sent to the priovisioning service to
identify phone software type. Value
is read only.
software-type
Text.
Max. 30
characters
Siemens SIP
[SIP];
Siemens HFA
[HFA]
Sent to the priovisioning service to
identify phone software type. Value
is read only.
part-number
Text.
Max. 25
characters
Sent to the priovisioning service to
communicate the phone’s part num-
ber. Value is read only.
slk-modules
Integer
For OpenStage 20E
and OpenStage 20,
the value is always
0
.
For OpenStage 15,
the value may be 0
or 1.
For OpenStage 40
to 80, the value may
be
0
,
1
or
2
.
Number of OpenStage Key
Modules. Sent to the provisioning
service in "ReadAllItems" message
response. Value is read only.
blf-modules
Integer
For OpenStage SIP
phones, the value is
always
0
.
Number of BLF Modules. Sent to the
provisioning service in
"ReadAllItems" message response.
Value is read only.
Item name
Type
Values
Description