c04.fm
A31003-S2000-R102-16-7620, 02/2016
Provisioning Service, Developer’s Guide
117
Nur für den internen Gebrauch
Phone Parameters - Administration
System
Bridging enabled
bridging-
enabled
Boolean
true
/
false
Default:
false
Determines whether
bridging is enabled
Dial plan enabled
dial-plan-
enabled
Boolean
true
/
false
Default:
false
If active, dialplan is en-
abled.
FPK program
timer
fpk-long-
press-timer
Enumer-
ation
0
to
5
Default:
2,
DPIP35:
0
0 (=OFF) means no long-
press timer is active.
If set to 2 (=ON) and an
FPK is pressed for 2 sec-
onds, it enters program-
ming mode.
Other values are not ac-
tive and reserved for fu-
ture use.
Relevant for OpenStage
15/40/60/80.
Available with OpenStage
V2R2.
Group pickup
tone allowed
group-pickup-
tone-allowed
Boolean
true
/
false
Default:
true
If enabled, an acoustic
signal is created for in-
coming pickup group
calls.
Group pickup as
ringer
group-pickup-
as-ringer
Boolean
true
/
false
Default:
true
Determines whether the
current ringtone or an
alert beep is used.
Group pickup
visual alert
group-pickup-
alert-type
Enumer-
ation
0
=Prompt;
1
=Notify;
Default:
0
Defines the user action
required to accept a pick-
up call.
BLF alerting
blf-tone-type
Enumer-
ation
0
=beep;
1
=ring tone
Default:
0
Selects the sound for indi-
cating an incoming call for
the monitored extension.
Available with OpenStage
V2R1.
MLPP ringer
Not relevant.
WBM Name
Item name
Type
Values
Description