MSR110D Programmer’s Manual UDN PM008 Rev. D
Section 5 – Configuration Commands 2002/3/19
Page
24
Uniform Industrial Corp.
Proprietary and Confidential
Total 44 pages
RE0 (52h 45h 00h)
-
-
-
-
Read EEPROM Data
Command Form: <09h 00h 03h 52h 45h 00h 1Dh>
1 The reader’s setting status is recorded in EEPROM. 98 bytes total.
2 The symbol “*” in this paragraph indicates “do not care”.
Byte1 and 2 in EEPROM
are 00h, 13h separately. They are identical characters.
Byte 3 in EEPROM
Table 5-28. Byte 3 of EEPROM Status
Bit
7
SS&ES
Status
Bit
6
LRC
Status
Bit
5
Bit
4
Bit
3
Bit & Parity
Bit
2
Bit
1
Bit
0
Baud Rate Status
0
Not
Send
0 Send 0
0
0
7
even 0 0 0 1200
1 Send
1
Not
send
0 0 1
7
odd
0 0 1 2400
*
*
* *
0
1
0
7
mark 0 1 0 4800
*
*
* *
0
1
1
7
space 0 1 1 9600
*
*
* *
1
0
0
8
none 1 0 0 19200
Byte 4 in EEPROM
Table 5-29. Byte 4 of EEPROM Status
Bit
7
Bit
6
Protocol
Bit
5
CTS Status
Bit
4
RTS Status
Bit
3
MSR 100 output
format
Bit
2
Bit
1
Bit
0
Transmitting Data
Track
0 1
0
0
Ignore
0
Always low
0
Disable
* * 0 Not Transmit Tk1
1 0
1
1 Consider 1
Low when
transmit data
1 Enable *
*
1
Transmit
Tk1
1
1
2 * * * * * * *
0
*
Not
Transmit
Tk2
*
*
* * * * * * * *
1
*
Transmit
Tk2
* *
*
*
*
*
*
*
0
0 * * Not
Transmit
Tk3
* *
*
*
*
*
*
*
1
1 * * Transmit
Tk3
Note: If never set “PC” command then bit 6 and bit 7 are 00, it means protocol 0.
Byte 5 in EEPROM
Table 5-30. Byte 5 of EEPROM Status
Bit
7
Bit
6
Bit
5
Bit
4
Address
(Hex code)
Bit
3
JIS Read
Head
Bit
2
Self-Arm
Mode
Bit
1
Bit
0
Buzzer
* * * *
*
0 Without 0
Disable * 0 Disable
* * * * *
1 With
1
Enable * 1 Enable
*
*
*
*
* *
* *
* *
*
*
*
*
*
*
* *
* *
* *
*
*