MSR110D Programmer’s Manual UDN PM008 Rev. D
Section 5 – Configuration Commands 2002/3/19
Page
19
Uniform Industrial Corp.
Proprietary and Confidential
Total 44 pages
TKx (54h 4Bh x)
-
-
-
-
Set Transmitting Data Tracks
x is an ASCII number (1-7)
Table 5-9. Transmit Tracks Setting
ASCII
Command Form (Hex)
Transmit Tracks
1
09h 00h 03h 54h 4Bh 31h 24h
Track 1
2
09h 00h 03h 54h 4Bh 32h 27h
Track 2
3
09h 00h 03h 54h 4Bh 33h 26h
Track 1 & 2
4
09h 00h 03h 54h 4Bh 34h 21h
Track 3
5
09h 00h 03h 54h 4Bh 35h 20h
Track 1 & 3
6
09h 00h 03h 54h 4Bh 36h 23h
Track 2 & 3
7
09h 00h 03h 54h 4Bh 37h 22h
Track 1, 2 & 3 (default)
AAx (41h 41h x)
-
-
-
-
Set Address
1 x is a binary byte (00h-0Fh)
2 Set address 00h: <09h 00h 03h 41h 41h 00h 0Ah>
SAx (53h 41h x)
-
-
-
-
Self -Arm Mode Enable/Disable
x = E(45h enable) or D(44h disable)
Table 5-10. Self-Arm Mode Setting
Command Form (Hex)
Self-Arm Mode
09h 00h 03h 53h 41h 44h 5Ch Disable
09h 00h 03h 53h 41h 45h 5Dh Enable (default)
SPx (53h 50h x)
-
-
-
-
Set Track Separator
1 x = Hex Code
2 x = 00h means do not send separator code
Table 5-11. Track Separator Setting
Command Form (Hex)
Track Separator
09h 00h 03h 53h 50h 00h 09h
Disable (default)
09h 00h 03h 53h 50h 0Dh 04h Enable
JHx (4Ah 48h x)
-
-
-
-
Set JIS Read Head
x = E(45h enable) or D(44h disable)
Table 5-12. JIS Read Head Setting
Command Form (Hex)
JIS Read Head
09h 00h 03h 4Ah 48h 44h 4Ch Without (default)