Product Specification / User Manual
Load Amplifier Cassette LVCpro-
S
© Copyright 2010 TRsystems GmbH , Systembereich Unidor LVCpro-SV13_E.doc Version 1.3 /08.11.10 Page 12 of
20
7. Setting of the Code-Switches
The adjustment of the analogous inputs and outputs will be implemented through
hexadecimal code and DIP-switches.
The adjustments will be implemented separately for each channel.
Channel / Sensor
Code-Switch
Function
Channel 1 + 2
SW1
Filter adjustment
Channel 1
SW201
Code-switch for capacitive (rough) amplification
Piezo Sensor 1
SW202
Code-switch for amplification adjustment(fine)
P102
Offset analogous output 1
P202
Offset analogous output peak value 1
Channel 2
SW401
Code-switch for capacitive (rough) amplification
Piezo Sensor 2
SW402
Code-switch for amplification adjustment(fine)
P302
Offset analogous output 2
P402
Offset analogous output peak value 2