D - 4 PROLOGGER SDI-12 IMPLEMENTATION
Command
Description
Sensor
Data Recorder
a!
Acknowledge
4
8
aI!
Send identification
4
8
aV!
Start verification
4
8
aM!
Start measurement
4
4
aD0!
Send data
4
8
Unused Commands
aM1...9!
Start additional Measurement
8
4
aD1...9!
Send additional Data
8
8
Extended commands
8
4
D - 4.1. DEFAULT SETTINGS
address = 0
retry = 10
# of channels = 2
SDI0 channel 1 address = 200
A0
SDI1 channel 2 address = 202
A1
SDI2 channel 3 address = 204
A2
SDI3 channel 4 address = 206
A3
SDI4 channel 5 address = 208
A4
ID string = 011UNIDATA 7001A 2200000<CR><LF>
VERIFY string = 00000<CR><LF>
START string = 00002<CR><LF>
D - 4.2. ALTERING SDI-12 SETTINGS
Change the PROLOGGER Configuration Setting (see Appendix D of the
STARLOG Version 3 Software Manual #6245) to adjust SDI-12 settings in
the PROLOGGER’s Configuration Table. Adjustments are:
address = 0…9
retry count =1…25
# of channels = 0…5
channel 0…4addr = n (location of 16 bit channel in the PROLOGGER
Register Block)
PROLOGGER Hardware
5