background image

4

SRWH-Series | Version 1.01

Safety

Tips and recommendations

It is necessary to observe the safety notes written in 
these operating instructions in order to reduce the risk of 
personal injuries and damages to property. 

2.2 Obligations of the operating company

of the operator

The operating company is the person who operates the 
floor jack for business or commercial reasons by her-
self, or leaves it to a third party for use or application, 
and who bears the legal product responsibility for the 
protection of the user, the staff or for third parties.

Obligations of the operating company

If the floor jack is used for commercial purposes, the 
operating company of the floor jack must comply with 
the legal working safety regulations. Therefore, the saf-
ety notes in this operating manual, as well as the safety, 
accident prevention and environment protection regula-
tions applying for the area of application of the floor jack 
must be met. The following applies in particular:

- The operating company must be informed about 

the applying industrial safety regulations and fur-
ther analyse hazards resulting from the special 
working conditions at the place of use of the floor 
jack. She must implement these in form of ope-ra-
ting manuals for the operation of the floor jack.

- During the entire lifetime of of the floor jack, the 

operating company must verify whether the oper-
ating manuals prepared by her correspond to the 
current status of the regulations, and must adapt 
these if necessary.

- The operating company must unambiguously reg-

ulate and determine the responsibilities for instal-
lation, operation, troubleshooting, maintenance 
and cleaning.

- The operating company must ensure that all per-

sons who work with the floor jack, have read and 
understood this manual. Furthermore she must in-
struct the staff in regular intervals and inform them 
about the hazards.

- The operator must provide the necessary protec-

tive equipment to the staff and order the use of the 
necessary protective equipment in a binding way.

Furthermore the operating company is responsible to 
keep the floor jack always in a technically flawless state. 
Thus, the following applies:

- The operator must ensure that the maintenance in-

tervals described in this manual are kept.

- The operator must have all safety devices che-

cked regularly for their good working order and 
their integrity.

2.3 Requirements to staff

Qualifications

The different tasks described in this manual represent 
different requirements to the qualifications ot the per-
sons entrusted with these tasks.

Only persons reliable working procedures can be ex-
pected from, are allowed to perform all works. Persons 
the responsiveness of which is affected by e. g. drugs, 
alcohol or medication, are not allowed to work with the 
machine.

CAUTION!

This combination of symbol and signal words indi-
cates a possibly dangerous situation which may 
lead to minor or light injuries if they are not avoided. 

ATTENTION!

This combination of symbol and signal words indi-
cates a possibly dangerous situation which may 
lead to property and environmental damages if they 
are not avoided. 

NOTE!

This combination of symbol and signal words indica-
tes a possibly dangerous situation which may lead to 
property and environmental damages if they are not 
avoided.

Tips and recommendations

This symbol highlights useful tips and recommenda-
tions as well as information for an efficient and trou-
ble-free operation. 

WARNING!
Danger in case of insufficient qualification 

ot the staff!

Insufficiently qualified persons cannot estimate the 
risks while using the floor jack and expose them-sel-
ves and others to the danger of severe or lethal inju-
ries. 
-  Have all works only performed by qualified per-

sons.

-  Keep insufficiently qualified persons out of the wor-

king area.

Summary of Contents for 6201121

Page 1: ...SRWH S ERIES SRWH 3002 EF Special Floor Jack SRWH 3001 SIL Operating Instructions SRWH 3001 SIL SRWH 3002 EF...

Page 2: ...3 1 1 Copyright 3 1 2 Customer service 3 1 3 Limitation of liability 3 2 Safety 3 2 1 Symbol explanation 3 2 2 Obligations of the operating company 4 2 3 Requirements to staff 4 2 4 General safety reg...

Page 3: ...on which then could be shared and be valuable to develop our products even further 1 3 Limitation of liability All information and notes in these operating instructions were summarised while taking ap...

Page 4: ...st in struct the staff in regular intervals and inform them about the hazards The operator must provide the necessary protec tive equipment to the staff and order the use of the necessary protective e...

Page 5: ...the specified max Load capacity of the floor jack is not exceeded It must be ensured that the ground is sufficiently stable to hold the load Lift loads only on level even and firm ground with the flo...

Page 6: ...fety regulations are observed the following residual risks remain when operating the floor jack All persons working with the floor jack must be aware of these residual risks and follow the instruction...

Page 7: ...he film is made of polyethylene PE and the cushioned parts of polystyrene PS Deliver these substances to a collection point for recyclable materials or to the waste disposal company which looks after...

Page 8: ...ver extension and screw the two pump lever parts together with the screw SRWH 3001 SIL model only Fig 6 Mounting the pump lever on the jack body Step 2 The pump lever socket is fixed in the lower posi...

Page 9: ...heck all parts for integrity and proper function 9 Operation DANGER Danger to life due to falling of the load Falling loads can cause serious injury or death Never exceed the specified maximum load st...

Page 10: ...nto the support frames by slowly turning the pump lever counterclockwise to open the drain valve 9 4 Lower the load Step 1 Turn the pump lever about its own axis to the right clockwise to close the dr...

Page 11: ...form in the hydraulic system of the floor jack and affect its function Step 1 Turn the pump lever around its own axis to the left to open the drain valve Step 2 Pump several times with the pump lever...

Page 12: ...se hydraulic oil of the same type Never mix different types of oil NOTE The removed oil must be disposed of separately Information about this can be obtained from the lubri cant manufacturer Problem P...

Page 13: ...il freight sea air express Address of dispatch Spare part orders which do not include the above indi cations may not be taken into consideration If the indi cations regarding the mode of dispatch are...

Page 14: ...14 SRWH Series Version 1 01 Spare parts 13 2 Spare parts drawings Spare parts drawing 1 SRWH 3001 SIL Fig 10 Spare parts drawing 1 SRWH 3001 SIL...

Page 15: ...Spare parts SRWH Series Version 1 01 15 Spare parts drawing 2 SRWH 3001 SIL pump Fig 11 Spare parts drawing 2 SRWH 3001 SIL pump...

Page 16: ...16 SRWH Series Version 1 01 Spare parts Spare parts drawing 1 SRWH 3002 EF Fig 12 Spare parts drawing 1 SRWH 3002 EF...

Page 17: ...Spare parts SRWH Series Version 1 01 17 Spare parts drawing 2 SRWH 3002 EF pump Fig 13 Spare parts drawing 2 SRWH 3002 EF pump...

Page 18: ...18 SRWH Series Version 1 01 Hydraulic plan 14 Hydraulic plan Fig 14 Hydraulic plan SRWH 3001 SIL top SRWH 3002 EF bottom SRWH 3002 EF SRWH 3001 SIL...

Page 19: ...121 SRWH 3002 EF 6201122 Serial number ______________________ Year of manufacture 20_____ Fill in these fields according to the information on the type plate complies with all the relevant provisions...

Page 20: ...www unicraft de...

Reviews: