12
When choosing where to install the device, adhere
to the following safety indications:
- Position the appliance in areas protected from
frost.
- Avoid installation in rooms with a corrosive or very
dusty atmosphere.
- The appliance must only be installed on a vertical
and solid wall which can support its weight.
3.4 - POsITIONING THE APPLIANCE
Clearance
3.5 - CONNECTION
The mains pressure must be within 1 and 3
bar (in the event of greater pressure install
a pressure reducer).
C (boil) (mix) *
Hot inlet from boiler
(integration)
1/2’’
F (boil) *
Cold water inlet to boiler
(integration)
1/2’’
C (cyl)
Domestic hot water outlet 1/2’’
F (acq)
Aqueduct cold water inlet 1/2’’
M (ss) **
Solar system flow
3/4’’
R (ss) **
Solar system return
3/4’’
(*)
LOOP pipe to be removed if the appliance is
connected to an integration boiler.
(**)
The piping must be insulated and secured
to the housing using the clamps
1-2
.
svb
SAFETY VALVE DRAIN/
CYLINDER
svs
(*)
SAFETY VALVE DRAIN/
sOLAR sYsTEM
Provide drain pipes with funnel and a siphon
that lead to a suitable drain, in correspond-
ence of Svb - Svs.
This drain must be controlled on sight.
If this precaution is not taken, triggering
of the safety valve can cause damage
to persons, animals and objects, for
which the manufacturer cannot be held
responsible.
(*) Can be ducted to a recovery receptacle.