10
2.4 - TECHNICAL DATA PLATE
Maximum solar operating temperature
°C
95
Minimum solar operating temperature
°C
30
Solar expansion vessel total capacity
l
18
Minimum solar circuit pressure
bar
1.5
Maximum solar circuit pressure
bar
6
DHW cylinder expansion vessel total capacity
l
6
Minimum domestic hot water circuit pressure
bar
0.5
Maximum domestic hot water circuit pressure
bar
6
Voltage/Frequency electric power supply
V/Hz
230/50
Maximum absorbed output
W
60
Protection rating
IP
20
CYLINDER
Total Capacity
l
147.6
Maximum DHW operating pressure
bar
10
Maximum heat exchanger operating pressure
bar
6
Maximum cylinder operating temperature
°C
95
Lower heat exchanger surface area
m ²
1.2
Max. absorbed output
kW
3.6
10/45°C DHW production (heat. 80/60)
l/h
900
2.3 - DOMEsTIC HOT wATER PRODUCTION
Without integration (only solar storage tank)
Temperature of
Cylinder
70°C
Temperature of
inlet water
10°C
Temperature of
delivery
45°C (Mixed Water)
Flow rate
12 l/min
After 17’
approx. 204 l at 45°C
(Flow rate 12 l/min - solar collector temp. 70°C - Mix T 45°C)
Time (sec)
Temperature (°C)