45
Maintenance instructions
ENGLISH
24
7
sPEED OUT OF
CONTROL
Alteration of the fan speed; the
speed is not reached.
Check fan operation
(18)
and
the connections.
26
8
sPEED OUT OF
CONTROL
Alteration of the fan speed; the
speed is above that requested.
Check fan operation
(18)
and
the connections.
6
8
HIgH TEMPErATUrE
Boiler temperature too high.
Check pump operation and if
needed clean the exchanger
(24)
8
NO
WATER
9
wATER DEFICIENCY
Insufficient water pressure and
consequent intervention of the
minimum water pressure - pres-
sure switch
( 13 )
.
Fill the heating circuit as de-
scribed in chap. 3.8 and wait
for the values to return within
default limits.
If needed, check the electri-
cal connections and replace
the minimum water pressure
switch.
16
10
EXcHANgEr
frEEZINg ( 24 )
Exchanger freezing is detected
If the heating sensor detects a
temperature below 2° C, burn-
er ignition is inhibited until the
sensor detects a temperature
above 5°C.
Disconnect the from the
power supply, close the gas
valve, defrost the exchanger
carefully.
LIMIT
THERM.
11
SAfETY THErMOSTAT
Intervention of the safety ther-
mostat
(10).
Press the unblock button on
the panel and/or check that the
thermostat or its connections
are not interrupted.
13
12
DOMESTIC HOT WATER
SENSOR
Domestic hot water sensor fault
(1).
Check the efficiency of the
sensor (see table Res/Temp)
(Par.4) and its connections.
12
13
HEATINg SENSOr (11)
Heating sensor fault.
Check the efficiency of the
sensor (see table Res/Temp)
(Par.4) and its connections.
38
14
FACTORY PARAMETERs
Alteration of the factory param-
eters due to possible electro-
magnetic interferences.
Press the unblock key; if the
anomaly persists, replace the
board.
Summary of Contents for KUTter R 28
Page 2: ...2 http www unicalag it prodotti domestico 50 condensazione gas 1335 kutter b...
Page 9: ...9 Caratteristiche Tecnhiche I TA L I A N O Questa pagina lasciata intenzionalmente in bianco...
Page 11: ...11 Informazioni generali I TA L I A N O Vista dall alto Vista da dietro KUTter R 28...
Page 12: ...12 KUTter B 28...
Page 13: ...13 Caratteristiche Tecnhiche I TA L I A N O Vista dall alto Vista da dietro KUTter B 28...
Page 47: ...47...
Page 48: ...2 http www unicalag it prodotti domestico 50 condensazione gas 1335 kutter b...
Page 56: ...9 Technical Features E N G L I S H This page is intentionally left blank...
Page 58: ...11 General information E N G L I S H Back view KUTter R 28 View from above...
Page 59: ...12 KUTter B 28...
Page 60: ...13 Technical Features E N G L I S H KUTter B 28 Back view View from above...
Page 94: ...47...
Page 95: ......
Page 96: ......