19
Technical Features
ENGLISH
2.5 - gENErAL fEATUrES
2.4.1 - DATA AccOrDINg TO ErP DIrEcTIvE
KUTTER
r 28
B 28
Appliance category
II
2H3P
II
2H3P
Minimum heat. circuit output (∆t 20 °C)
l/min
2,97
2,97
Minimum heating circuit pressure
bar
0,5
0,5
Maximum heating circuit pressure
bar
3
3
Primary circuit content
l
2,2
2,2
Maximum operating temperature in heat.
°C
85
85
Minimum operating temperature in heat.
°C
30
30
Expansion vessel total capacity
l
12
12
Expansion vessel pre-load
bar
1
1
Maximum system capacity
(max temp. calc.)
l
246,5
246,5
Minimum domestic hot water circuit flow rate
l/min.
-
2,5
Minimum domestic hot water circuit pressure
bar
-
0,5
Maximum domestic hot water circuit pressure
bar
-
8
Domestic hot water specific flow rate (∆t 30 °C)
l/min.
-
17,6
Domestic hot water flow rate limiter
l/min.
-
12
Production of D.H.W. in continuous operation with ∆t 45 K
l/min.
-
8,56
Production of D.H.W. in continuous operation with ∆t 40 K
l/min.
-
9,62
Production of D.H.W. in continuous operation with ∆t 35 K
l/min.
-
11,00
Production of D.H.W. in continuous operation with ∆t 30 K
l/min.
-
12,83
Production of D.H.W. in continuous operation with ∆t 25 K
(*)
l/min.
-
15,4
Temperature adjustable in domestic hot water mode
°C
-
25-65
Voltage/Frequency electric power supply
V-Hz
230/50
230/50
Fuse on the power supply
A (F)
4
4
Protection rating
IP
X5D
X5D
Net weight
kg
86
Gross weight
kg
99
DHW Expansion vessel pre-load
bar
2,5
Expansion vessel DHW total capacity
l
3
Capabilities water tank
l
50
(DHW available at a temp. of 45°C in (**)
l.
-
151
F factor
-
2
R factor
-
(*) Mixing water
(**) the first 10 mins of draw-off with storage tank water at 60°C and cold water at 10°C
Description
KUTTER
r 28
B 28
symbol
Unit
Nominal Heat Output
Pnominale
kW
26,9
26,9
Seasonal space heating energy
efficiency
ƞ
s
%
93
93
Seasonal efficiency class in
heating mode
A
A
for cH only and combination boilers: useful heat output
Useful Heat Output in high-temperature regime
(Tr 60 °C / Tm 80 °C)
P
4
kW
15,76
15,76
Useful efficiency at nom. heat output
in high-temperature regime (Tr 60 °C / Tm 80 °C
ƞ
4
%
97,0
97,0
Useful heat output at 30% of nom. heat output
in low-temperature regime (Tr 30 °C)
P
1
kW
5,23
5,23
Useful efficiency at 30% of nom. heat output
in low-temperature regime (Tr 30 °C)
ƞ
1
%
108,6
108,6
Range-rated boiler: YES / NO
NO
NO
Auxiliary electricity consumption
At full load
elmax
kW
0,095
0,146
At part load
elmin
kW
0,051
0,023
In stand-by mode
P
SB
kW
0,001
0,001
Other items
Stand-by heat loss
P
stb
kW
0,084
0,084
Emissions of nitrogen oxides
NOx
mg/kWh
43,0
43,0
for cH & DHW production boilers
Declared load profile
-
L
Energy efficiency in DHW production mode
ƞ
wh
%
53,2
53,2
Daily electricity consumption
Qelec
kWh
-
-
Daily fuel consumptionl
Qfuel
kWh
21,9
21,9
Inside sound power level
Lwa
dB (A)
53,2
53,2
Seasonal efficiency class
in DHW production mode
-
b
Summary of Contents for KUTter R 28
Page 2: ...2 http www unicalag it prodotti domestico 50 condensazione gas 1335 kutter b...
Page 9: ...9 Caratteristiche Tecnhiche I TA L I A N O Questa pagina lasciata intenzionalmente in bianco...
Page 11: ...11 Informazioni generali I TA L I A N O Vista dall alto Vista da dietro KUTter R 28...
Page 12: ...12 KUTter B 28...
Page 13: ...13 Caratteristiche Tecnhiche I TA L I A N O Vista dall alto Vista da dietro KUTter B 28...
Page 47: ...47...
Page 48: ...2 http www unicalag it prodotti domestico 50 condensazione gas 1335 kutter b...
Page 56: ...9 Technical Features E N G L I S H This page is intentionally left blank...
Page 58: ...11 General information E N G L I S H Back view KUTter R 28 View from above...
Page 59: ...12 KUTter B 28...
Page 60: ...13 Technical Features E N G L I S H KUTter B 28 Back view View from above...
Page 94: ...47...
Page 95: ......
Page 96: ......