35
Installation Instructions
ENGLISH
2) Minimum output adjustment
- Operate the boiler in “calibration” mode at MINI-
MUM OUTPUT (see 3.11.1)
- Once the burner is on check that the CO
2
“MINI-
MUM” value corresponds to that indicated in the
table “NOZZLES - PRESSURE”.
- Correct it if needed removing the tap
‘’Q’’
and
turning (with a screwdriver) the screw
“R”;
CLOCKWISE to increase it, ANTICLOCKWISE
to decrease it
The following instructions are intended
exclusively for
authorised service per-
sonnel
.
1) Maximum output adjustment
- Operate the boiler in “calibration” mode at MAXI-
MUM OUTPUT (see 3.11.1)
- Once the burner is on check
that the CO
2
“MAXIMUM” value corresponds to
that indicated in the table “NOZZLES - PRES-
SURE”.
- if it does not correspond, correct it by turning the
screw
“s”
CLOCKWISE to decrease it, ANTI-
CLOCKWISE to increase it.
3) Conclusion of the basic calibrations
- once the CO
2
values at minimum and maximum
output have been checked and any adjustments
have been made (sections 1-2):
- disable the timed “calibration” function by switch-
ing off the
main
switch.
- close the flue gas inspection sample points of the
intake and exhaust terminal
-
check that there are no gas leaks.
3.12 - ADJUSTINg THE BUrNEr
(S)
ADJUSTMENT SCREW
MAXIMUM OUTPUT
(R)
ADJUSTMENT SCREW
MINIMUM OUTPUT
For proper operation, the CO
2
values
must be calibrated with particular at-
tention, observing the values indicated
in the table.
- Remove the cap and insert the CO2 analysis
probe in the flue gas sample point of the intake/
exhaust terminal, see chap. 3.11.2.
All boilers leave the factory already cali-
brated and tested, however in the event
the gas valve recalibration is required:
Attention, during these operations do not take
any samples in domestic hot water mode.
Summary of Contents for KUTter R 28
Page 2: ...2 http www unicalag it prodotti domestico 50 condensazione gas 1335 kutter b...
Page 9: ...9 Caratteristiche Tecnhiche I TA L I A N O Questa pagina lasciata intenzionalmente in bianco...
Page 11: ...11 Informazioni generali I TA L I A N O Vista dall alto Vista da dietro KUTter R 28...
Page 12: ...12 KUTter B 28...
Page 13: ...13 Caratteristiche Tecnhiche I TA L I A N O Vista dall alto Vista da dietro KUTter B 28...
Page 47: ...47...
Page 48: ...2 http www unicalag it prodotti domestico 50 condensazione gas 1335 kutter b...
Page 56: ...9 Technical Features E N G L I S H This page is intentionally left blank...
Page 58: ...11 General information E N G L I S H Back view KUTter R 28 View from above...
Page 59: ...12 KUTter B 28...
Page 60: ...13 Technical Features E N G L I S H KUTter B 28 Back view View from above...
Page 94: ...47...
Page 95: ......
Page 96: ......