16
KON 1 C24
KON 1 C28
KON 1 C35
Appliance category
II
2H3P
II
2H3P
II
2H3P
Minimum heat. circuit output (∆t 20 °C)
l/min
2,1
3,1
3,1
Minimum heating circuit pressure
bar
0,5
0,5
0,5
Maximum heating circuit pressure
bar
3
3
3
Primary circuit content
l
2,2
2,8
2,8
Maximum operating temperature in heat.
°C
85
85
85
Minimum operating temperature in heat.
°C
30
30
30
Expansion vessel total capacity
l
7
10
10
Expansion vessel pre-load
bar
1
1
1
Maximum system capacity (max temp. calc.)
l
144
205
205
Minimum domestic hot water circuit flow rate
l/min.
2,0
2
2,0
Minimum domestic hot water circuit pressure
bar
0,5
0,5
0,5
Maximum domestic hot water circuit pressure
bar
6
6
6
Domestic hot water specific flow rate (∆t 30 °C) ‘‘
D
’’ l/min.
11,2
13
16
Domestic hot water flow rate limiter
l/min.
-
-
-
Production of D.H.W. in continuous operation with ∆t 45 K
l/min.
7,34
8,6
10,1
Production of D.H.W. in continuous operation with ∆t 40 K
l/min.
8,26
9,7
11,4
Production of D.H.W. in continuous operation with ∆t 35 K
l/min.
9,44
11,1
13,0
Production of D.H.W. in continuous operation with ∆t 30 K
l/min.
11,0
12,9
15,2
Production of D.H.W. in continuous operation with ∆t 25 K (*)
l/min.
13,2
15,5
18,3
Voltage/Frequency electric power supply
°C
38-60
38-60
38-60
Fuse on the power supply
V-Hz
230/50
230/50
230/50
Maximum absorbed output
A (F)
4
4
4
Protection rating
IP
X5D
X5D
X5D
Net weight boiler
kg
40
41
41
Gross weight boiler
kg
43
44
44
F factor
1
2
2
R factor
(*) mixed