General information

1.5 -

SAFETY WARNINGS

WARNING!
The installation, adjustment, and servicing of this appliance must be carried out by a competent person
and installed in accordance with the current standards and regulations.  Failure to correctly install this
appliance could cause injury to persons, animals or damage to property.  The manufacturer shall not be
held liable for any injury and/or damage.

DANGER!

Servicing or repairs of the appliance must be carried out by UNICAL authorised service technicians; UNICAL
recommends drawing up a service contract.  Bad or irregular servicing  could compromise the safe operation of
the appliance, and could cause  injury to persons, animals or damage to property for which UNICAL shall not be
held liable.

Modifications to parts connected to the appliance

Do not carry out any modifications to the following parts:
-

the boiler

-

to the gas, air, water supply pipes and electrical current

-

to the flue pipe, safety relief valve and its drainage pipe

-

to the constructive components which influence the appliance’s safe operation

WARNING!

When tightening or loosening the screw pipe connections, use only adequate fork spanners.
The improper use and/or the use of inadequate equipment can cause damages (for example water or gas
leakages).

WARNING!

Indications for appliances operating with propane gas
Ensure yourself that before installing the appliance the gas tank has been purged.
For a correct purging of the tank contact the liquid gas supplier or a competent person who has been legally
authorized.
If the tank has not been correctly purged problems could occur during ignition.
If this occurs contact the liquid gas tank’s supplier.

Smell of gas

If you smell gas follow these safety indications:
-

Do not turn on or off electrical switches

-

Do no smoke

-

Do not use the telephone

-

Close the main gas tap

-

Open all windows and doors where the gas leakage has occurred

-

Inform the gas society or a company specialized in installing and servicing heating systems

Explosive and easily inflammable substances

Do not use or leave explosive or easily inflammable material (as for example: petrol, paint, paper) in the room
where the appliance has been installed.

Warning!
The 

appliance

 must not be used by persons with limited capacities, physical, mental and sensory.

These persons must be previously instructed and watched during the operations of transition.

Summary of Contents for IDRONIK TS 13

Page 1: ...00333639 2nd edition 04 2011 ISTRUCTIONS FOR INSTALLER USER AND SERVICE MAN IDRONIK TS 13 Instantaneousgas water heater type C 88...

Page 2: ...over to the user 3 1 5 Safety warnings 4 1 6 Data badge 5 1 7 General warnings 6 2 TECHNICAL FEATURES AND DIMENSIONS 7 2 1 Technical features 7 2 2 Dimensions 7 2 3 Main components 8 2 4 Operational d...

Page 3: ...it is recommended to adjust the domestic hot water temperature as near as possible to the one you really require We recommend you to check the state of cleanliness of the heat exchanger at the end of...

Page 4: ...loosening the screw pipe connections use only adequate fork spanners The improper use and or the use of inadequate equipment can cause damages for example water or gas leakages WARNING Indications fo...

Page 5: ...ss A Features of the D H W circuit 7 Pn Nominal Output 8 Qmax Nominal max input 9 PW Max D H W Working Pressure 10 T max Max D H W Working Temperature B Electrical Data 11 Electrical supply 12 Electri...

Page 6: ...or by means of the appropriate shutdown devices Do not obstruct the intake outlet terminal ducts In the event of failure and or faulty functioning of the appliance switch off the appliance Do not atte...

Page 7: ...2009 142 EC ElectroMagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC 2 TECHNICAL FEATURES AND DIMENSIONS 2 2 DIMENSIONS COMPONENTS DESCRIPTION Two section burner Ultraflat...

Page 8: ...imum Input Nominal Output Pn Minimum Output Efficiency at nominal load Efficiency at partl load Gas type Category Nominal gas feeding pressure Burner nozzle N Off Burner nozzle Smoke evacuation type k...

Page 9: ...onstrictions and that no other appliance s flue outlets have been fitted unless the chimney is serving more than one heating appliance according to the specific standards and regulations in force The...

Page 10: ...al duct Kit 60 100 for air intake and smoke eva cuation is packaged separate cardboard DO NOT DISPERS IN THE ENVIRONMENT A 430 mm B 755 mm C 230 mm 3 2 STANDARD CODES FOR INSTALLA TION IDRONIK TS is o...

Page 11: ...hich could reach the water exchanger and affect the proper running of the water heater b Check that the appliance has been preset for operating with the gas type available This is verifiable via the i...

Page 12: ...ce by device Check with the gas cock turned off that there are no gas leaks During the 2nd quarter of the hour from the start of the test no pressure reduction should be detected by the pressure gauge...

Page 13: ...l the supplier s contractual or extra contractual responsibilities 3 8 ROOM VENTILATION The appliance has to be installed in a convenient room in conformity with the rules inforce and particularly bec...

Page 14: ...allow to the outside the possible condensate Example 1 LATERAL AIR INTAKE SMOKE EVACUATION Example 2 REAR AIR INTAKE SMOKE EVACUATION pendenza 2 00262980 Coaxial kit 60 100 supplied as standard made o...

Page 15: ...n correctly earthed in compliance with the regulations in force The gas and water feeding pipes cannot be used as ground plates Ensure that the above safety electrical requirements subsist in case of...

Page 16: ...ure is 35 C the maximum settable temperature is 60 C adjustable 1 by 1 C Normally the outlet temperature of hot water is for a shower of about 40 C Adjust the hot water flow rate C up to the necessary...

Page 17: ...ature through the button B according to your own needs It is good to get familiar with the appliance commands by repeating several times the ignition procedure after the installation or the first use...

Page 18: ...ervice works have been done perform always the following operations Open the cold water inlet cock if previously closed Open the gas gate valve Switch on the electrical supply to the appliance and tur...

Page 19: ...ulty gas valve Actions Check gas valve and its connec tions Effect STOP 6 ERROR CODES Maximum temperature ptotection Actions Control the circulation Effect STOP E3 E3 E3 E3 E3 Obstructed discharging s...

Page 20: ...g info unical ag com The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold ne...

Reviews: