User’s operating instructions

Freezing prevention

In case of extended periods of operation below
zero, it is suggested:

1 - Close the cold water tap.

2 - Turn the water flow rate adjusting knob to its
“MAX” position.

3 - Turn the drainage valve ‘‘D‘‘ and extract it,
re-position it when the residual water has been
completely drained.

PRECAUTIONS
-

 If you open the water tap before switching on

the water heater, this will not start automatically.

When taking a shower, in order to avoid being

scalded, make sure the water temperature is
at an acceptable value.

After using water at high temperature, in order

to avoid the risk of being scalded at the next
use, adjust the  water temperature at an
acceptable value.

The dust, in time, could cause the lockout of
the water heater and compromise the combus-
tion with increase of the carbon monoxide. It is
then necessary to call a qualified technician
for cleaning and remove the dust  and soot
every six months in order to make sure the
combustion products are evacuated regularly.

The water heater must be installed vertically.

Safety precautions

Gas accidents prevention

Make sure the flame extinguishes after the use.

Check the soundness of the gas connections
with a soap solution. If a gas leack should be
detected open immediately the windows and
don‘t switch on or use electrical appliances, or

connect or disconnect plugs from sockets,
because flames or sparks can provoque
explosions.

Adjust the water flow rate through the knob

‘‘C‘‘

and the hot water temperature through the

button 

‘‘B‘‘

,  according to your own needs. It is

good to get  familiar with the appliance commands
by repeating several times the ignition procedure
after the installation or the first use.

When the water tap is open while the ignition
button if off, the water heater doesn‘t work: only
cold water runs through it. If hot water is needed,
you have just to push the button  

‘‘A‘‘

.

When the water tap is closed, the water heater is
switched off, but the fan continues working still
for a few seconds.

The outlet water temperature doesn‘t
correspond exactly to the pre-set temperature.

Fire Prevention

In case of lack of ignition or lack of D.H.W.
drawing close the gas and water taps.

Don’t place onto the water heater towels or
clothing.

Don’t store flammable substances in the pro-
ximity of the water heater.

Prevention from carbon monoxide poisoning

This water heater takes the air for combustion
and discharges the combustion products throu-
gh the coaxial duct, that, for this reason, has to
be installed  as specified in the paragrapf 3.9.  A
wrong installation could create dangers up to
the death.

A too low or too high water presure can cause
an anomalous combustion.
In these cases don’t use the water heater up to
when the water pressure returns to the normal
value.

Behaviour in anomalous conditions

In case of noisy combustion, smoke at the out-
let or poor combustion, close the gas gate val-
ve, switch off the appliance and contact the
service center.

Prevention of scald injury (if the casing is
removed)

The qualified technician , after removing the
casing, must check the flame via the sight
glass.
During this operation it is important to take care
and stay at a minimum distance of  300mm.

Summary of Contents for IDRONIK TS 13

Page 1: ...00333639 2nd edition 04 2011 ISTRUCTIONS FOR INSTALLER USER AND SERVICE MAN IDRONIK TS 13 Instantaneousgas water heater type C 88...

Page 2: ...over to the user 3 1 5 Safety warnings 4 1 6 Data badge 5 1 7 General warnings 6 2 TECHNICAL FEATURES AND DIMENSIONS 7 2 1 Technical features 7 2 2 Dimensions 7 2 3 Main components 8 2 4 Operational d...

Page 3: ...it is recommended to adjust the domestic hot water temperature as near as possible to the one you really require We recommend you to check the state of cleanliness of the heat exchanger at the end of...

Page 4: ...loosening the screw pipe connections use only adequate fork spanners The improper use and or the use of inadequate equipment can cause damages for example water or gas leakages WARNING Indications fo...

Page 5: ...ss A Features of the D H W circuit 7 Pn Nominal Output 8 Qmax Nominal max input 9 PW Max D H W Working Pressure 10 T max Max D H W Working Temperature B Electrical Data 11 Electrical supply 12 Electri...

Page 6: ...or by means of the appropriate shutdown devices Do not obstruct the intake outlet terminal ducts In the event of failure and or faulty functioning of the appliance switch off the appliance Do not atte...

Page 7: ...2009 142 EC ElectroMagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC 2 TECHNICAL FEATURES AND DIMENSIONS 2 2 DIMENSIONS COMPONENTS DESCRIPTION Two section burner Ultraflat...

Page 8: ...imum Input Nominal Output Pn Minimum Output Efficiency at nominal load Efficiency at partl load Gas type Category Nominal gas feeding pressure Burner nozzle N Off Burner nozzle Smoke evacuation type k...

Page 9: ...onstrictions and that no other appliance s flue outlets have been fitted unless the chimney is serving more than one heating appliance according to the specific standards and regulations in force The...

Page 10: ...al duct Kit 60 100 for air intake and smoke eva cuation is packaged separate cardboard DO NOT DISPERS IN THE ENVIRONMENT A 430 mm B 755 mm C 230 mm 3 2 STANDARD CODES FOR INSTALLA TION IDRONIK TS is o...

Page 11: ...hich could reach the water exchanger and affect the proper running of the water heater b Check that the appliance has been preset for operating with the gas type available This is verifiable via the i...

Page 12: ...ce by device Check with the gas cock turned off that there are no gas leaks During the 2nd quarter of the hour from the start of the test no pressure reduction should be detected by the pressure gauge...

Page 13: ...l the supplier s contractual or extra contractual responsibilities 3 8 ROOM VENTILATION The appliance has to be installed in a convenient room in conformity with the rules inforce and particularly bec...

Page 14: ...allow to the outside the possible condensate Example 1 LATERAL AIR INTAKE SMOKE EVACUATION Example 2 REAR AIR INTAKE SMOKE EVACUATION pendenza 2 00262980 Coaxial kit 60 100 supplied as standard made o...

Page 15: ...n correctly earthed in compliance with the regulations in force The gas and water feeding pipes cannot be used as ground plates Ensure that the above safety electrical requirements subsist in case of...

Page 16: ...ure is 35 C the maximum settable temperature is 60 C adjustable 1 by 1 C Normally the outlet temperature of hot water is for a shower of about 40 C Adjust the hot water flow rate C up to the necessary...

Page 17: ...ature through the button B according to your own needs It is good to get familiar with the appliance commands by repeating several times the ignition procedure after the installation or the first use...

Page 18: ...ervice works have been done perform always the following operations Open the cold water inlet cock if previously closed Open the gas gate valve Switch on the electrical supply to the appliance and tur...

Page 19: ...ulty gas valve Actions Check gas valve and its connec tions Effect STOP 6 ERROR CODES Maximum temperature ptotection Actions Control the circulation Effect STOP E3 E3 E3 E3 E3 Obstructed discharging s...

Page 20: ...g info unical ag com The Unical declines every responsibility for the possible inaccuracies if owed to errors of transcript or press Also reserves the right to bring those changes that it will hold ne...

Reviews: