6.5.2

 

Refrigerant diagram of the model HP_OWER 500N 

LP

LS

 

Pr

HP

DT

FL

FL

M

SE

OUT

IN

4WV

EEV

NRV

NRV

LR

LR

ST

PV

PV

CP

LR

P

V

NRV

NRV

NRV *

V *

NRV *

C

C

NRV

 

INVERTER COMPRESSOR 

ST 

COMPRESSOR INLET TEMPERATURE 

DT 

COMPRESSOR OUTLET TEMPERATURE 

HP 

HIGH PRESSURE TRANSDUCER 

Pr 

HIGH PRESSURE FLOW SWITCH 

LP 

LOW PRESSURE TRANSDUCER 

LS 

LIQUID SEPARATOR 

4WV 

CYCLE REVERSING VALVE 

LR 

LIQUID RECEIVER 

EEV 

ELECTRONIC EXPANSION VALVE 

FL 

FILTER 

AXIAL FAN 

SE 

OUTDOOR AIR TEMPERATURE SENSOR 

CIRCULATOR ON BOARD UNIT 

IN 

WATER INLET TEMPERATURE 

OUT 

WATER OUTLET TEMPERATURE 

CP 

CAPILLARY 

ON-OFF SOLENOID VALVE

 

NRV 

NO RETURN VALVE 

PV 

PRESSURE CHECK VALVE 

 

6.6

 

ELECTRICAL CONNECTIONS 

Check if the power supply circuit meets the unit’s electric nominal data (tension, phases,  frequency) reported on the label 

attached on the right-side panel of the unit. The wiring must be done in accordance to the wiring diagram attached to the unit and 

in conformity with the national and international norms in force (attempting to provide a general magneto-thermic circuit breaker, 

differential circuit breakers for each electric line, proper grounding for the plant, etc.). Power cables, electric protections and line 

fuses have to be sized according to the specifications listed in the wiring diagram enclosed with the unit and in the electrical data 

contained in the table of technical characteristics (see Paragraph 0). 

 

Because of the presence, inside the machine, of EMC filters for compliance with EMC limits (interference emission and 

interference immunity), earth fault currents up to 250 mA of intensity can be detected.  

For proper installation, electrically connect the unit with a dedicated line; if you use a residual current circuit breaker, 

choose a four-pole one, with a trigger threshold of 300 mA and delayed triggering (super-resistant, characteristic K). 

The machine must be installed in TN-S/TT power supply grounding systems. 

The electrical installation must be carried out in accordance with norms in force. 

 

WARNING: The supply voltage’s fluctuations cannot exceed ±5% of the nominal value. Should this tolerance not be 

respected, please contact our technical department. 

 

WARNING: The power supply have to respect the listed limits: failing this, warranty will terminate immediately. 

Before any operation on the unit, be sure that the power supply is disconnected. 

WARNING: The water flow switch (B component in the previous hydraulic circuit and factory installed) has ALWAYS to 

be connected following the indications listed in the wiring diagram. Never bridge the water flow switch connections in 

the terminal board. The guarantee will not be valid if the water flow switch connections are altered or not correctly 

performed. 

 

Install upstream of each unit an adequate  protection and disconnection device of the electric power with delayed 

characteristic curve, with at least 3 mm contact opening and with an adequate capacity of breaking and differential 

protection. 

A good grounding is required; the manufacturer is not responsible for damage caused in case of lack  of good 

grounding. 

Use cables that meet the regulations in force in different countries. 

 

If the lightning risk is high, the unit must be protected, the risk assessment must comply with the CEI EN 62305-2 

regulation. 

If there is a possibility that a lightning can strike the area around the appliance, stop the operation of the unit and 

disconnect the system upstream switch. 

Make sure to ground the unit. 

Do not ground the unit with pipes or lightning rods. 

A poor grounding of the unit can result in electrocution. 

Warning: Electrostatic discharges can damage the electronic components, before performing any work; ground the 

electrostatic charge by touching objects such as water or heating pipes. 

Before working on the control panel it is OBLIGATORY to: 

 

Turn off the units from control panel (displayed “OFF”). 

 

Place the general differential QF switch in “OFF” state. 

Summary of Contents for HP_OWER 250N

Page 1: ...User s and Installer s Manual 250 350 500 N...

Page 2: ...optional module terminal block CODE 00264034 13 7 START UP 14 7 1 POWER ON OF THE UNIT 14 8 INDICATIONS FOR THE USER 14 9 SHUTDOWNS FOR LONG PERIODS 14 10 MAINTENANCE AND PERIODICAL CONTROLS 15 10 1...

Page 3: ...unit it refers to It has to be stored in a safe place away from the dust and moisture It has to be accessible to all users who shall consult it any time they are in doubt on how to operate the equipm...

Page 4: ...well as any applicable local laws and authorized specifications The execution of all works must be performed by skilled and qualified personnel competent in the existing rules in different countries T...

Page 5: ...ce s health and safety including 89 391 CEE 89 686 CEE 89 655 CEE 2009 104 CE 86 188 CEE and 77 576 CEE directives Every employer shall implement such norms and ensure that workers to respect them It...

Page 6: ...TWA 1000 ml m for each of the two components Respiratory protection For rescue and maintenance operation in storage tanks use self contained respirator The vapors are heavier than air and can cause su...

Page 7: ...ng the unit immediately check its integrity The unit left the factory in perfect condition any eventual damage has to be questioned to the carrier and recorded on the Delivery Note before signing it T...

Page 8: ...rubber band between basement and unit base frame It is also possible to install anti vibration supports springs or rubbers to keep vibrations at a very low level An absolute care has to be taken to en...

Page 9: ...ing water for the plant please refer to UNI 8065 CAUTION The INVERTER control system is able to manage minimum water contents in the plant up to a value of 75 liters for the model HP_OWER 250 of 105 l...

Page 10: ...R 4WV CYCLE REVERSING VALVE LR LIQUID RECEIVER EEV ELECTRONIC EXPANSION VALVE FL FILTER M AXIAL FAN SE OUTDOOR AIR TEMPERATURE SENSOR P CIRCULATOR ON BOARD UNIT IN WATER INLET TEMPERATURE OUT WATER OU...

Page 11: ...must be installed in TN S TT power supply grounding systems The electrical installation must be carried out in accordance with norms in force WARNING The supply voltage s fluctuations cannot exceed 5...

Page 12: ...utral conductor N 6 6 2 User s terminal block L1F1 L1F1 L2F1 L2F1 L3F1 L3F1 N 1 N 2 N 1 N 2 PE 1 PE 1 L3 1 L3 2 L3 1 L3 2 HPS HPS 12AC1 12N1 12AC1 12N1 DO1 DO3 DO5 DO4 DO6 DO7 DO2 DO7N DO6N DO5N DO4N...

Page 13: ...the unit s front panel For the configuration of the functionalities please check the control manual supplied with the unit DO1E DO3E DO5E DO4E ST5E ST6E DO2E DO1EN DO1EN DO1E DO3E DO5E DO4E ST5E ST6E...

Page 14: ...hanges of this seasonal operating mode have to be avoided in order to prevent severe damages to compressors WARNING When you first install and start up the unit make sure that the unit is working prop...

Page 15: ...entering the inner components of the unit be sure that the power supply is disconnected The compressor s heads and discharge pipes are usually at high temperature levels Be very careful when operating...

Page 16: ...rolled substances and for this reason it has to be subjected to the mentioned norms A particular care is recommended during service operations in order to reduce as much as possible any refrigerant lo...

Page 17: ...0 27 04 29 1 36 21 38 4 36 36 38 3 Power input 2 kW 6 48 6 35 9 1 8 96 12 49 12 45 EER 2 W W 3 24 3 33 2 96 3 02 2 90 2 92 SEER 5 W W 3 98 4 00 4 03 Heating Heating capacity 3 kW 24 72 27 2 24 57 27 2...

Page 18: ...70 dB A 74 dB A 77 dB A Precautions for installation and maintenance Read precautions for installation and maintenance at specific chapters on user s and installation s manual PRODUCT FICHE HP_OWER f...

Page 19: ...5 94 Tj bivalent temperature Pdh 16 4 kW Tj bivalent temperature COPd 2 36 Tj operation limit temperature Pdh 13 8 kW Tj operation limit temperature COPd 1 76 For air to water heat pumps Tj 15 C if T...

Page 20: ...89 Tj bivalent temperature Pdh 20 5 kW Tj bivalent temperature COPd 2 12 Tj operation limit temperature Pdh 17 7 kW Tj operation limit temperature COPd 1 83 For air to water heat pumps Tj 15 C if TOL...

Page 21: ...5 76 Tj bivalent temperature Pdh 31 4 kW Tj bivalent temperature COPd 2 23 Tj operation limit temperature Pdh 26 6 kW Tj operation limit temperature COPd 1 73 For air to water heat pumps Tj 15 C if TO...

Page 22: ...W Tj 12 C COPd 3 68 Tj bivalent temperature Pdh 11 6 kW Tj bivalent temperature COPd 1 78 Tj operation limit temperature Pdh 9 8 kW Tj operation limit temperature COPd 1 56 For air to water heat pumps...

Page 23: ...W Tj 12 C COPd 3 88 Tj bivalent temperature Pdh 20 7 kW Tj bivalent temperature COPd 1 59 Tj operation limit temperature Pdh 17 6 kW Tj operation limit temperature COPd 1 33 For air to water heat pump...

Page 24: ...W Tj 12 C COPd 3 51 Tj bivalent temperature Pdh 23 0 kW Tj bivalent temperature COPd 1 78 Tj operation limit temperature Pdh 19 6 kW Tj operation limit temperature COPd 1 56 For air to water heat pump...

Page 25: ...with the UNI EN ISO 9614 2 13 ELECTRIC DATA OF THE UNIT AND AUXILIARIES Power supply of the unit V Hz 400 3 50 Remote control circuit V Hz 12 1 50 Control board circuit V Hz 12 1 50 Fans power supply...

Page 26: ...ve circulator with the possibility of choice between constant P and variable P 15 2 MODEL HP_OWER 500N Configuration with integrated circulator control via 0 10 volt analogic signal Configuration with...

Page 27: ...SS CURVES OF THE HYDRONIC CIRCUIT We obtain the pressure head of the circulating pump from the addition of the head losses of the hydronic circuit and the available head pressure For example for the m...

Page 28: ...rmal insulation which reduces at very low outside temperatures the heat losses of 2 compared to a standard insulation 18 2 SSL Cod 00264038 The super silenced unit with SLN accessory is provided not o...

Page 29: ...lity study and evaluation of changes to be made according to your requests The maximum temperature that can be maintained at the outlet of the evaporator is 25 C Higher temperatures up to a maximum of...

Page 30: ...ssure drops correction factor The water flow rate and pressure drop correction factors are to be applied directly to the values given for operation without glycol The water flow rate correction factor...

Page 31: ...Max Packing height mm Max Packing height with AXITOP Versions SSL mm HP_OWER 250N 350N 1673 1906 1785 2030 HP_OWER 500N 1745 1910 1890 2055 Some units could be shipped with another type of packaging...

Page 32: ...he units is indicative and useful to present the main components and can therefore vary from the purchased one The front panel is closed The front panel is open at 180 Disconnecting switch with door l...

Page 33: ...n models there are also other components installed in an additional plate at the bottom left side of the electric box On board terminal block and user s terminal block Support boards Transformer Drive...

Page 34: ......

Page 35: ......

Page 36: ...s It also reserves the right to modify its products as deemed necessary or useful without jeopardising their essential features 46033 casteldario mantova italia tel 39 0376 57001 fax 39 0376 660556 in...

Reviews: