Setting automatic weekly programme

The heating programme provides for 6 daily time bands for temperature levels, numbered from 1 to 6. The 

time bands can be set between 00:00 and 24:00 in 10 minute increments. Each temperature level can 

be set between 7°C and 32.5°C in 0.1°C increments. Therefore any combination of time and temperature 

during the day can be programmed, and different for each day of the week.

The preset automatic programme is:

MONDAY - FRIDAY

BAND 1

BAND 2

BAND 3

BAND 4

BAND 5

BAND 6

START TIME

6:30

8:00

12:00

14:00

18:00

22:30

TEMPERATURE LEVEL

21°C

18°C

21°C

18°C

21°C

16°C

SATURDAY - SUNDAY

BAND 1

BAND 2

BAND 3

BAND 4

BAND 5

BAND 6

START TIME

8:00

10:00

12:00

14:00

18:00

22:30

TEMPERATURE LEVEL

21°C

21°C

21°C

18°C

21°C

16°C

Follow the instructions given below to modify the preset automatic programme.

1.  Press the button     . If DHW programming is enabled, select the radiator symbol with the buttons 

   

  and confirm with thew button      and numebre 1 of  DAY 1 is show down in a box to indicate 

  that time band 1 of Monday can be modified

2.  Press the button      . The hours and minutes start flashing: use button            to change the 

  time band start time in 10 minutes increments. By keeping the button presses the hours will change   

 rapidly.

3.  Press the button    . The room temperature inside the house starts flashing: use the buttons

   to change the temperature level in 0.1 °C increments. By keeping the button pressed the temperature  

  will change rapidly.

4.  Press the button    . The 6 daily time bands flash

5.  Then press the button      to disply time band 2 of Monday, modifiable by repeating step 2 to 4.,

6.  The remaining time bands can be displayed by selecting bands 3, 4, 5 or 6 with buttons 

  and    

  repeating step 5

7.  The programme setting for the following day can now be selected:

  a.  Press the button        to display time band DAY 2. The Thuesday programme can be modified  

 

    by repeating steps 2 to 6.

  b.  To copy the Monday programme to Tuesday, press the button      . To copy the same programme   

    also to the other days of the week, press the button       repeatedly.

Important! 

When setting the programme make sure each band has a different start time.

Heating - Domestic Hot Water Temperature Adjustment

Heating 

Press the button 

    : the display shows the current heating circuit water temperature setting, adjustable 

using the buttons 

   in 1°C increments. Press any button to exit the menu.

DHW 

Press the button 

   : the display shows the current domestic hot water temperature setting, adjustable 

using the buttons 

    in 1°C increments (only if function is enabled). Press any button to exit the menu.

Summary of Contents for EASYr

Page 1: ...E N G L I S H REMOTE CONTROL ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL...

Page 2: ...e instructions contained in the manuals supplied with the boiler Index 1 Genera features 3 2 Package Contents 3 3 Description buttons and symbols 3 4 Application 5 5 Installation 6 6 Easy User Guide 7...

Page 3: ...ogramming 0 Deactivated P2 Pre Heating Function 0 Deactivated P3 Max number of daily time bands 6 P4 Heating min temperature P5 Filling the system 0 Deactivated P6 Temperature unit of measure selectio...

Page 4: ...Manual room temperature increase button BRIDGE 1 TEST mode button 2 LED behind the button DISPLAY KEY 11 Heating programme time bands 12 Day of week 13 Holiday function button copy heating DHW program...

Page 5: ...5 E N G L I S H Connect the Bridge to the TA1 OT ter minals of the boiler after removing the jumper from TA2 4 Application Bridge can be hidden inside the boiler...

Page 6: ...RF Bridge by prising with a screwdriver at A e B Then fix the back of the bridge to the wall with the set of screws supplied running the two wires inside the rectangular hole at the bottom near the t...

Page 7: ...ediately the search of synchrony This is showed by the symbol flashing for max 2 minu tes and when it stops the synchrony has occurred lf there is no communlcation and the error E94 appears the system...

Page 8: ...Control will function according to the automatic weekly programme displaying the 6 time bands the time band active at that moment is di splayed in a box If the box is not shown this means that the cur...

Page 9: ...utes increments By keeping the button presses the hours will change rapidly 3 Press the button The room temperature inside the house starts flashing use the buttons to change the temperature level in...

Page 10: ...utton associated with a different operation mode Telephone contact input GSM Normal Remote Control operation is ensured as long as the telephone contact remains open The closing of this contact indica...

Page 11: ...button pressed for 3 seconds 2 The display shows the CU parameter Press the buttons to modify the compen sation curve by increments of 1 unit By keeping the button pressed the value will change rapidl...

Page 12: ...same day so that the room temperature set by the user is reached at the start of the programmed time band The Remote Control calculates an initial hypothetical Pre activation time if the programmed r...

Page 13: ...The display shows parameter P5 Set to 0 using the buttons to deactivate the electric filling device Set to 1 using the buttons to activate Automatic system filling 5 Press any other button to exit the...

Page 14: ...display activates fault E94 and the symbol once the power is restored it is necessary to wait 15 minutes After which the symbol becames fixed and RF communication is avaible again Diagnostic The remo...

Page 15: ...15 E N G L I S H...

Page 16: ...erves the right to bring those changes that it will hold necessary to it own products or profits without jeopardizing its essential characteristics 46033 casteldario mantova italia tel 39 0376 57001 f...

Reviews: