10
Holiday Function
The Holiday Function is used to switch off heating (also domestic hot water production for boilers with a
storage tank) for a given period of time, from 1 hour to 45 days, adjustable in 1 hour increments. This makes
it possible to save energy when away from home, whereas the previously set operation mode resumes
as soon as the Holiday function ends. Heating is activated only if the room temperature falls below 5°C:
freezing protection function.
Follow the instructions given below to activate and set the Holiday function.
1. Press the button . The symbol starts flashing and the hours minutes became -00:01, which is
the time remaining before the end of the Holiday function
2. Use the buttons to extend the time remaining until the end of the Holiday function in 1 hour
increments (-00:01 means 1 hour; -45:00 means 45 days). By keeping the button pressed the
time and days will change rapidly.
3. During the Holiday function the display will continue to show the time remaining until the end of the
function.
To cancel the Holiday function press the button or any other button associated with a different operation
mode.
Telephone contact input (GSM)
Normal Remote Control operation is ensured as long as the telephone contact remains open. The closing
of this contact, indicated on the display with the symbols ( ), can be used to force the Remote Control to
switch off heating or to set the room temperature to a preset fixed value.
Follow the instructions given below to activate and set the two functions.
1. Keep the button pressed for 3 seconds.
2. The display shows the CU parameter.
3. Press the button 9 times.
4. The display shows parameter P8.
Set to 0 using the buttons to switch off heating when the contact is closed.
Set to 1 using buttons means of parameter P9) when the contact is closed.
ad un valore fi sso preimpostato (attraverso il successivo parametro P9) alla chiusura del contatto.
5. Press the button .
6. The display shows parameter P9
Set the room temperature value that the Remote Control will adjust when the contact is closed
(if parameter P8 is set to 1) by pressing the buttons
in 0.1°C increments. By keeping the
button pressed the temperature will change rapidly.
7. Press any other button to exit the menu.
Modification of the Remote Control operating mode on opening or closing of telephone conctact can occur
in a maximum time of 120 seconds.